Assembly and function
OPTIMUM
M A S C H I N E N - G E R M A N Y
29 / 11 / 2006
Page
4
Assembly and function CNC Controller III and VI ; Version 2.0.1
©
20
06
GB
2
Assembly and function
The step motor control is working in half-step operation. The supply of the step motors amounts
to maximum 40 volts DC. The operation control boards are protected against any kind of short
circuit. Any malfunctions are displayed by flashing up of the red LED. After correcting the
malfunction, it is sufficient to switch off the controller and to switch it on again.
3
Capacity and general data
The following information give the dimensions and weight of the CNC controller III and VI and is
the manufacturer’s authorised machine data.
4
Unpacking and connection
INFORMATION
When the CNC controller is delivered, check immediately that the machine is not been damaged
during transport and that all components are included. Also check that no fastening screws have
come loose.
4.1
Delivery volume
CNC controller without control boards
IEC power connector
operating manual
4.2
Commissionning
4.2.1
Safety
Use the CNC controller only under the following conditions:
The CNC controller is in proper working order.
The CNC controller is used as prescribed.
The operating manual is observed.
All anomalies should be eliminated immediately. Stop the CNC controller immediately in the
event of any abnormality in operation and make sure it cannot be started-up unintentionally or
without authorisation.
Power supply
CNC controller III
CNC controller VI
Connection
230V ~ 50 Hz 300VA
Fusing
1,6 A slow-blow fuse
General data
Potential-free relay output
-
4 pcs 10 A per
relay
Dimensions: Length x Width x Height [ mm ]
295 x 230 x 145
540 x 275 x 125
Environmental conditions
Temperature
5 - 35 °C
Humidity
25 - 80 %