background image

optimascale.com

OP-918 INDICATOR

USER’S MANUAL

(Pallet Jack Indicator)

Содержание OP-918

Страница 1: ...optimascale com OP 918 INDICATOR USER S MANUAL Pallet Jack Indicator...

Страница 2: ...rations and Set Up 1 Features 2 Specifications 3 Power Supply 4 Display and Key Descriptions 5 Operating Instructions 6 8 Calibration 9 10 Indicator Parameter Settings 11 14 Helpful Definitions 15 Con...

Страница 3: ...e sure the weight is not over the Max capacity as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the s...

Страница 4: ...ature Accumulation weighing Printer optional Splash proof keyboard and display Power saving mode NTEP approved for 5 000 divisions Rechargeable battery Technical Parameters Stimilating voltage 3 3VDC...

Страница 5: ...3 SPECIFICATIONS OP 918 OP 918M...

Страница 6: ...charged 7 Indicator charge lasts up to 22 hours Battery Please charge the internal battery fully before first time use A 110 to 220V AC adapter should be provided with your indicator Please use only...

Страница 7: ...OFF to enter into calibration 3 Combined with the TOTAL key to check the Accumulative sum lb The weight is shown in pounds kg The weight is shown in kilograms hold Shows you are in Hold mode Gross Sho...

Страница 8: ...to tare out the weight Tare Function The Tare function is used when you only wish to see the current change in weight not the entire amount of weight that is on the scale When the indicator is in gros...

Страница 9: ...adding together will flash on the display followed by the total The total will display by flashing between 2 sets of numbers There are 8 digits in total the display will flash 4 at a time the first 4...

Страница 10: ...to Hold If the weight on the scale is above 20d 20 x division and is stable the indicator will hold that weight on the screen for 3 seconds then go back to general weighing Pressing the hold key is un...

Страница 11: ...this scale by using TOTAL to move the cursor to the right and UNIT and ZERO to move the values down and up The C4 channel is used to enter in the max capacity of the scale Make sure to enter the corre...

Страница 12: ...the calibration weight on the scale 29 If the scale does not show the value of the calibration weight check that the pallet jack is level on the ground and on a flat surface and recalibrate 30 Unload...

Страница 13: ...nit C01 1 kg 2 lb 3 gram 4 oz Note for calibration only kg or lb are allowed Decimal Setting C02 0 no decimal 1 0 0 2 0 00 3 0 000 4 0 0000 Division Graduation Setting readability of the least signifi...

Страница 14: ...4 Average hold for animal weighing averages the weight from a sample of 3 seconds Inner Code Display C15 check the inner code raw data Set Date C16 Set date from left to right year month day Set Time...

Страница 15: ...5 5 digital filter strength 6 6 digital filter strength Note The higher the number the higher the filter strength Noise Filter C29 0 turn off noise filter 1 1 digital filter strength 2 2 digital filte...

Страница 16: ...Alarm C14 000000 Inner Code Display C15 Set Date C16 Set Time C17 Communication Setting C18 0 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracking C22 0 5 Zero Trackin...

Страница 17: ...the time allowed for the scale to fall within the zero tracking range tolerance and still qualify to be zero d Overload Range Weight allowance that is out of the set calibrated range Adds a tolerance...

Страница 18: ...s of 350 at most 4 wire or 6 wire load cell connections are both okay Please contact us directly if you have other special needs for your application There are two connection methods between the load...

Страница 19: ...See Q A section ERR1 During calibration weight is not used or the weight is above the max capacity Use correct weight within the defined range ERR2 During calibration the weight is below the minimum r...