15
CHECK WEIGHING CONFIGURATION
Weighing mode press
to go enter parameters
Display
Function
1. FinAL
Final value
2. SP1
SP1 value
3. SP2
SP2 value
4. SP3
SP3 value
F. FALL
Free fall value
6. oVer
Over value
7. UndEr
Under value
8. Z.bAnd
Zero band
Warning: set FinAL > SP1 > SP2 > SP3 > F. Fall
set Sq01=1: net weigh
Signal
Output Condition
Relay Output
SP1
Net ≥ Final-SP1
J1
SP2
Net ≥ Final-SP2
J2
SP3
Net ≥ Final-SP3
J3
Free Fall
Net ≥ Final-F.FALL
J4
Set Sq01=3:
Signal
Output Condition
Relay Output
HI
Net ≥ SP1
J1
OK
SP1 ≥Net ≥ SP2
J2
LO
Net < SP2
J3