9.1 Light intensity adjustment
1.
Rotate the light adjustment ring
①
on the right side of the
microscope body. (Fig. 7)
As an alternative:
1.
Move the mouse button on the upper left corner of the screen.
2.
The Main Control Panel appears (see chapter 10.1 a).
3.
Adjust the illumination using the Camera Control Panel of the
built-in software.
9.2 Coarse focus tension adjustment
1.
To adjust the focusing tension, hold the left knob
②
and ro
-
tate the right knob
③
. (Fig. 8)
• Clockwise rotation increases the tension while counter-
clockwise rotation loosens it.
•
Adjust the focusing tension to appropriate position, to pre
-
vent the microscope body dropping during observation, and
also make focusing stable.
9.3 Parfocality adjustment
1.
Rotate the zoom adjustment ring
④
to the minimum magni
-
fication. (Fig. 9)
2.
While observing on the monitor, focus the specimen.
3.
Rotate the zoom adjustment ring
④
to the maximum mag
-
nification.
4.
Observe the image on the monitor: if it is not clear, rotate the
focusing knob to make it sharp.
5.
Return zoom adjustment ring to the minimum magnification.
Now parfocality adjustment should be set.
9.4 Focusing
Put the sample to be observed on the stand plate and focus the
sample using the focusing knobs.
•
If necessary adjust the height of the microscope head along
the pillar: unlock the fixing knob
⑤
, move the microscope to
the desired height and lock the fixing knob
⑤
after setting the
height of the microscope. (Fig. 10)
• In order to prevent accidental lowering of the system
due to imperfect locking of the fixing knob, it is advis
-
able to also use the drop prevention ring
⑥
.
9. Use of the microscope
F
Fig. 10
ig. 10
⑤
⑥
①
Содержание INSPECTION SYSTEMS Series
Страница 1: ...Ver 2 1 2021 INSTRUCTION MANUAL INSPECTION SYSTEMS Series Model IS 01 IS 01SMD...
Страница 14: ...Page 14 10 Use of the software 10 1 Menu Interface a Control...
Страница 15: ...Page 15 b Measurement...
Страница 33: ...Modello IS 01 IS 01SMD Serie INSPECTION SYSTEMS MANUALE DI ISTRUZIONI Ver 2 1 2021...
Страница 46: ...Pagina 46 10 Uso del software 10 1 Interfaccia del Menu a Controllo...
Страница 47: ...Pagina 47 b Misurazioni...
Страница 65: ...Ver 2 1 2021 MANUAL DE INSTRUCCIONES Serie INSPECTION SYSTEMS Modelo IS 01 IS 01SMD...
Страница 78: ...P gina 78 10 Uso del software 10 1 Interfaz del men a Control...
Страница 79: ...P gina 79 b Medici n...
Страница 97: ...Ver 2 1 2021 MANUEL D UTILISATION S rie INSPECTION SYSTEMS Mod le IS 01 IS 01SMD...
Страница 105: ...Page 105 C t arri re PORT USB POUR CL USB CONNECTEUR DE C BLE HDMI PORT USB POUR SOURIS CONNECTEUR D ALIMENTATION...
Страница 110: ...Page 110 10 Utilisation du logiciel 10 1 Interface du menu a Contr le...
Страница 111: ...Page 111 b Mesures...
Страница 129: ...Ver 2 1 2021 BEDIENUNGSANLEITUNG INSPECTION SYSTEMS Series Modell IS 01 IS 01SMD...
Страница 137: ...Seite 137 R ckseite USB ANSCHLUSS F R USB STICK HDMI KABE LANSCHLUSS USB ANSCHLUSS F R MAUS STROMVERSOR GUNGSSTECKER...
Страница 142: ...Seite 142 10 Verwendung der Software 10 1 Men Schnittstelle a Kontrolle...
Страница 143: ...Seite 143 b Messung...
Страница 161: ...Ver 2 1 2021 MANUAL DE INSTRU ES S rie INSPECTION SYSTEMS Modelo IS 01 IS 01SMD...
Страница 169: ...P gina 169 Parte de tr s PORTA USB PARA PEN DRIVE CONECTOR DE CABO HDMI PORTA USB PARA RATO CONECTOR FONTE DE ALIMENTA O...
Страница 174: ...P gina 174 10 Uso do software 10 1 Interface do menu a Controlo...
Страница 175: ...P gina 175 b Medi o...