12. Durability
12.1. Electrical Characteristics
Withstand voltage
AC 1500 V per 60 seconds, 10 mA or less
Insulation resistance
DC 500 V, 2 M
Ω
or higher
Current leakage
250
μ
A or less / AC 250 V 60 Hz
Power line noise immunity
± 1kV and higher
12.2. Static Electricity
Air discharge:
±8 kV max. (No malfunction)
±15 kV max. (No destruction)
Contact discharge:
±6 kV max. (No malfunction)
Measurement environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance:
330
Ω
Capacitor charging:
150 pF
12.3. Shock
12.3.1.
Drop Test (with individual packaging)
No defect occurred after the following drop test.
Drop test: Drop the scanner from a height of 200 cm onto a concrete floor (three
times in each of 6 angles).
Figure 12: Drop test
12.4. Vibration Strength
No malfunction occurred after the following vibration test.
Vibration Test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6 m/s
2
(2G) and sweep for 6 minutes in non-operating state.
Repeat this routine 10 times in each X, Y, Z direction. (Total elapsed time of vibration
test: 180 minutes.)