5.4. Charging Current
Parameter Specification
Note
500 mA or lower
When connected to RS-232C (when using AC adaptor)
Output: 6 V, 750 mA
CRD-3101 while charging
200 mA or lower
When connected to USB, use high power port (500
mA).
Testing Conditions
Operating temperature: 25° C
Charging Temperature: 0 to 40° C
Battery charging operation may be stopped when the scanner is charged at
the temperature higher than 40° C.
Battery charging operation may be stopped when the power supply voltage
impressed to the charging terminals exceeds the range of 3 to 6 V.
Note: Model names of AC adaptors dedicated to CHG-3101 and CRD-3101.
- Model for OSE and OPTICON: GP-ACGN13T-K4-2
- Model for Japan and North American Market: GP-ACGN13U-K4-2
5.5. Battery Operating Time and Charging Time
Parameter Specification
Note
Idle 1
About 55 hours
Without connection to communication line.
Idle 2
About 48 hours
With connection to communication line.
Battery Life
In use
About 25 hours
Without connection to communication line and
scanning once in every 5 seconds.
Charging
time 1
About 5 hours
When using CHG-3101 or CRD-3101 and connected
to RS-232C.
Charging Time
Charging
time 2
About 10 hours
When using CRD-3101 and connected to USB (bus
power supply).
Note: Battery life may be shorter than specified above when the quality of the battery