background image

Opticon 

OPR 3101 

Specifications Manual 

 
 
 
 

 

17 

7.4.2. 

Skew Angle and Dead Zone 

Skew angle: 

β

 = ±50° (Excluding dead zone) 

Dead zone: 

β

 = ±8° (There are some areas in which decoding fails due to 

specular reflection) 

 

Figure 6: Skew and dead zone 

Содержание OPR 3101

Страница 1: ...Rugged Wireless Laser Barcode Scanner OPR 3101 The OPR 3101 scanner uses Bluetooth technology for wireless transmission of scanned barcode data Specifications Manual ...

Страница 2: ...ts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental da...

Страница 3: ...Main Battery 10 5 3 Current Consumption 10 5 4 Charging Current 11 5 5 Battery Operating Time and Charging Time 11 5 6 Operating Indicators 12 5 6 1 LED Indicators 12 6 Optical Specifications 13 6 1 Laser Scan Specifications 13 6 2 Laser Scan Standards 13 6 2 1 Laser Scan Tilt 13 6 2 2 Curvature of Scan 13 7 Technical Specifications 14 7 1 Print Contrast Signal PCS 14 7 2 Minimum Resolution 14 7 3...

Страница 4: ... via RS 232C 25 9 4 3 Default Settings 3 3 Settings to Connect to Host via USB 26 10 Serial Number and Labeling 26 11 Packaging Specifications 27 11 1 Individual Packaging Specification 27 11 2 Collective Packaging Specification 28 12 Durability 29 12 1 Electrical Characteristics 29 12 2 Static Electricity 29 12 3 Shock 29 12 3 1 Drop Test with individual packaging 29 12 4 Vibration Strength 29 12...

Страница 5: ...ing 35 Table of Figures Figure 1 Ambient light immunity 9 Figure 2 Configuration of OPR 3101 10 Figure 3 Laser scan tilt and curvature 14 Figure 4 Depth of field 15 Figure 5 Pitch 16 Figure 6 Skew and dead zone 17 Figure 7 Tilt angle 18 Figure 8 Curvature 19 Figure 9 Serial number diagram 26 Figure 10 Individual packaging 27 Figure 11 Collective packaging 28 Figure 12 Drop test 29 Figure 13 Auto t...

Страница 6: ...ng for heavy duty applications The OPR 3101 is enclosed in a rugged housing sealed to IP 54 standards that withstands repeated drops of up to two meters onto concrete This scanner is suitable for use not only in offices or shops but also in warehouses Bluetooth technology for wireless communication The OPR 3101 supports Bluetooth with Class 2 output power It enables data communication at distances...

Страница 7: ...orean Postal Authority Code MicroPDF417 Code 11 PDF417 Code 39 Code 93 Code 128 GS1 128 EAN 128 GS1 Databar RSS IATA Industrial 2of5 Interleaved 2of5 ISBN ISMN ISSN Matrix 2of5 MSI Plessey S Code Telepen Tri Optic UK Plessey 3 Physical Features 3 1 Dimensions W 68 0 x D 155 0 x H 165 0 mm 3 2 Weight 250 g excludes the weight of a 40 gram battery pack ...

Страница 8: ...ng Temperature and Humidity Temperature 10 to 60 C Humidity 5 to 95 4 2 Charging Temperature Temperature 0 to 40 C Note Battery charging may stop when the scanner is charged at a temperature higher than 40 C 4 3 Storage Temperature and Humidity Temperature 20 to 60 C Humidity 5 to 95 ...

Страница 9: ...tions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet zone 10 mm N W ratio 1 2 5 Distance 150 mm Angle see note below α 0 β 15 γ 0 Curvature R Power supply voltage 3 7 V Direct light or specular reflection from a light source should be prevented from entering the acceptance area Note α β and γ respectively represent pitch skew and tilt Please s...

Страница 10: ...power supply and interface section Figure 2 Configuration of OPR 3101 5 2 Main Battery The main battery is a lithium ion secondary battery Nominal capacity 1620 mAh Nominal voltage 3 7 V When discharging 0 2 CA 5 3 Current Consumption Parameter Specifications Notes Idle 1 30 mA typ Without connection to communication line Idle 2 35 mA typ With connection to communication line In use Average 165 mA...

Страница 11: ... to 6 V Note Model names of AC adaptors dedicated to CHG 3101 and CRD 3101 Model for OSE and OPTICON GP ACGN13T K4 2 Model for Japan and North American Market GP ACGN13U K4 2 5 5 Battery Operating Time and Charging Time Parameter Specification Note Idle 1 About 55 hours Without connection to communication line Idle 2 About 48 hours With connection to communication line Battery Life In use About 25...

Страница 12: ... that the scanned data is being stored to the memory of the scanner Blue Blinking Shows that the scanner is making a connection to wireless communication line Lighting Shows a successful connection to wireless communication line Wireless Connection Red Lighting Shows a failure or error in making a connection to a wireless communication line Shows that the scanner has disconnected the wireless comm...

Страница 13: ...t scanning performance 6 2 Laser Scan Standards 6 2 1 Laser Scan Tilt Laser scanning tilt is the vertical difference between both ends of a laser scan line Measure it in the middle of the laser scan line Less than 1 2 angle in vertical direction from the scan origin mirror motor Up to 3 1 mm when measured at a point 150 mm from the scan origin The skew angle of this measurement was 0 6 2 2 Curvatu...

Страница 14: ...rcode black Space white Margin white Background of label black Power supply voltage 3 7 V Decoding test Approve the performance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 seconds or less 7 1 Print Contrast Signal PCS 0 45 or higher over 70 of reflectivity of space and quiet zone PCS Reflectance of white bar Reflectance of black bar Reflectance ...

Страница 15: ...is measured from the edge of the scanner The scanning range is within the circular arc centered on the scan origin Figure 4 Depth of field Symbology Resolution Decode depth mm PCS Code 39 1 0 mm 40 720 0 9 Code 39 0 5 mm 20 430 0 9 Code 39 0 25 mm 20 230 0 9 Code 39 0 15 mm 20 120 0 9 Code 39 0 127 mm 30 100 0 9 ...

Страница 16: ...ample N W Ratio 1 2 5 Angle α 0 β 15 γ 0 Curvature R Resolution Symbology PCS Quiet Zone Digit 1 0 mm Code 39 0 9 25 mm 1 0 5 mm Code 39 0 9 18 mm 3 0 25 mm Code 39 0 9 10 mm 8 0 15 mm Code 39 0 9 7 mm 10 0 127 Code 39 0 9 5 mm 4 7 4 Pitch Skew and Tilt 7 4 1 Pitch Angle α 35 Figure 5 Pitch ...

Страница 17: ...R 3101 Specifications Manual 17 7 4 2 Skew Angle and Dead Zone Skew angle β 50 Excluding dead zone Dead zone β 8 There are some areas in which decoding fails due to specular reflection Figure 6 Skew and dead zone ...

Страница 18: ...e edge of the scanner Label Pitch Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angle Pitch Angle Skew Angle β 15 Tilt Angle γ 0 Tilt Angle Pitch Angle α 0 Skew Angle β 15 Skew Angle Dead Zone Pitch Angle α 0 Tilt Angle γ 0 Curvature R ...

Страница 19: ...rmance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 8 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample Distance 60 mm from the edge of the scanner Label PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Angle Skew Angle β 15 ...

Страница 20: ...configuration 1 to 1 One scanner to one host system Do not connect multiple scanners to one host system Scanner operating mode while connected to the host system Master OPR 3101 Slave CRD 3101 and other Bluetooth devices Security mode Authentication enabled These settings can be configured using menu barcodes Encryption Encryption is linked to the authentication setting and cannot be enabled or di...

Страница 21: ...ance may be negatively impacted or their communications may be disconnected by other devices using the same absorption rate Baud rate and communication distance are affected by obstacles wave conditions or a device at the other end This product is equipped with an antenna Bringing this product too close to a metallic object may affect communication Anticipated interference distance is 10 m or less...

Страница 22: ...Readable Codes Symbology Read Transmit Code Length Transmit CD Calculate CD Set Prefix Set Suffix Other UPC A X CR UPC A Add on X X CR UPC E X CR UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Chinese Post 2of5 X X X CR Codabar NW 7 X X CR Not transmit ST SP Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 93 X X CR Code 128 X X CR GS1 128 EAN UCC 128 X ...

Страница 23: ...X CR Trioptic X CR Not transmit ST SP UK Plessey X CR Notes In the Reading column means Enable reading and X means Disable reading In the Transmit code length column means Transmit code length and X means Do not transmit code length In the Transmit CD column means Transmit check digit and X means Do not transmit check digit In the Calculate CD column means Calculate check digit and X means Do not ...

Страница 24: ...dundancy Other options Read 2 times redundancy 1 for the following symbologies and lengths Code 11 with length 5 Code 39 with length 5 IATA Industrial 2of5 Interleaved 2of5 with length 8 MSI Plessey with length 4 NW 7 Codabar with all lengths Trigger switch Enable Trigger repeat Disable Auto trigger Disable Read time 2 seconds when trigger enabled Margin check Normal Buzzer duration 50 ms Buzzer t...

Страница 25: ...uetooth device address Bluetooth address auto connect Enabled Authentication Enabled automatically done Bluetooth Options Encryption Enabled The default interface between the CRD 3101 and the host is set to RS 232C When using a USB connection between the CRD 3101 and the host the connection must be made to the USB HID of the cradle Do not connect to CNPC when using the OPR 3101 and the CRD 3101 9 ...

Страница 26: ...ull key code Caps Lock control No Caps Lock Intercharacter delay No delay 10 Serial Number and Labeling The labels shown below are affixed to the scanner Figure 9 Serial number diagram Serial number label Product name serial number date of manufacture Laser caution label This product is a Laser Class 2 product Model name label Information on all the certifications logos and ID numbers ...

Страница 27: ...57 M A D E I N JA P A N M odel N o O P R 3101 S pec N o UF1O PR3101 S er i al N o Q uant i t y 1 R o BAR CODE LABEL for BOX 3A0002 D o not f ol d at t he B ar C ode P osi t i on w hen st i ck t h e L ab el on t o t h e C o r n e r o f B o x D i spl ay f or t he ser i al N o f r om 000001 t o 999999 S am e num ber as t he scanner N um ber of seven di gi t s C ont i nuous N um ber U S E R S M A N U ...

Страница 28: ... 11 Collective packaging Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal weight in the European Union ...

Страница 29: ...vice compliant with IEC 61000 4 2 Discharge resistance 330 Ω Capacitor charging 150 pF 12 3 Shock 12 3 1 Drop Test with individual packaging No defect occurred after the following drop test Drop test Drop the scanner from a height of 200 cm onto a concrete floor three times in each of 6 angles Figure 12 Drop test 12 4 Vibration Strength No malfunction occurred after the following vibration test Vi...

Страница 30: ...ic or mechanical shock 14 Trigger and Read Options The OPR 3101 has an optional auto trigger setting which starts barcode reading automatically by using sensor detection When auto trigger is enabled a laser beam is emitted and points to the auto trigger area The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used Auto trigger distance 40 mm from...

Страница 31: ...not been detected for a set number of scans Continuous read mode The reader will produce as much data as it can decode even if it is reading the same symbol This mode is mainly used for demonstration and diagnosis Conditions Moving speed 100 10 mm s the moving direction is not specified Angle Vertical to the edge of the scanner Environmental temperature and humidity Room temperature and humidity E...

Страница 32: ...1 15 3 EMC EN55022 EN55024 VCCI Class B This is a Class B product to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instr...

Страница 33: ...fied Radio Equipment It does not have a radio station license in Japan The following activities are prohibited under the Radio Law Remodeling and disassembly Peeling off the certificate label 15 7 State of California Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate To comply with California Perchlorate Best Practice Regulations and the Law for th...

Страница 34: ...throw the scanner into the fire Do not forcibly bend the cables at low temperatures 16 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 16 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not place the product near a radio or a TV receiver as the scanner may cause reception problems The scan...

Страница 35: ...Opticon OPR 3101 Specifications Manual 35 17 Mechanical Drawing Dimensions 165 H x 68 W x 155 D Excluding protruding portion Figure 14 Mechanical drawing ...