![Opticon OPI-3601 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/opticon/opi-3601/opi-3601_specification-manual_1642022019.webp)
OPI-3601
Specifications Manual
13
7.6.
Pitch, Skew and Tilt
Pitch :
α
= ±50°
Skew :
β
= ±50°
Tilt :
γ
= ±180°
<Conditions>
Bar Code Sample
: 0.33 mm UPC specified in Chapter 7.1
Distance
: 105 mm from the front edge of the scanner
Curvature
: R =
∞
* For the pitch angle and tilt angle measurement, set the skew angle
β
= +15°
Figure 6: Pitch, Skew and Tilt
7.7.
Curvature
0.33 mm 12-digit UPC
: R
≧
20 mm
0.15 mm 10-digit Codabar : R
≧
16 mm
<Conditions>
Bar Code Sample
: 0.33 mm UPC, 0.15 mm Codabar specified in Chapter 7.1
Distance
: 85 mm from the front edge of the scanner
Angle
:
α
= 0°,
β
=
+
15°,
γ
= 0°
Figure 7: Curvature
Note: Scanning may fail due to the specular reflection of LED illumination when the reflectivity is high.