OPI-3601
Specifications Manual
4
Item
Specification
Note
This scanner is an Exempt Risk Group LED product.
LED safety
IEC 62471-1:2006 Exempt Risk Group
Peak Wavelength:
624 nm
EMI/RFI
VCCI / EN55022 / FCC Class-B
For residential,
commercial and light-
industrial environments
Product safety
CE Marking
Regu
latory
Electromagnetic compatibility
(EMC)
EN55024 (EN61000-6-1) Class-B
For residential,
commercial and light-
industrial environments
No destruction
15 kV (Apply static electricity 50 times to the
surface of the scanner)
ESD immunity
No malfunction
Contact discharge (direct / indirect): ±6 kV
Air discharge (direct):±8 kV
Condition:
IEC:61000-4-2
compliant
Frequency
80 ~ 1000 MHz
Level 3
V/m
Radio-
frequency
electromagnetic
field. Amplitude
modulation
AM 80%
(AM)
Condition:
IEC61000-4-3
compliant
Voltage
Alternating-current input cable: ±1 kV
Pulse
5 / 50 ns (Tr / Tw)
Fast transient
Frequency 5
kHz
Condition:
IEC61000-4-4
compliant
Pulse
1.2 / 50 ns (Tr / Th)
From L to P : ±2 kV (closed-loop voltage)
Surge
Voltage
From L to L : ±1 kV (closed-loop voltage)
Condition:
IEC61000-4-5
compliant
Frequency
0.15 ~ 80 MHz
Level 3
V
Radio-
frequency
common mode
AM 80%
(AM)
Condition:
IEC61000-4-6
compliant
Frequency
50 and 60 Hz
Power
frequency
magnetic field
Level 3
A/m
Condition:
IEC61000-4-8
compliant
Dip 1
Drop 30%, 0.5 cycles
Dip 2
Drop 60%, 5 cycles
Immunity Test
Voltage dip,
momentary
voltage drop,
fluctuation
Momentary
drop
Drop > 95%, 250 cycles
Condition:
IEC61000-4-11
compliant
Dimensions
Approx. 56.0 × 108.1 × 148.6
(WDH mm)
Physical
Feature
s
Weight Approx.
85g
Excluding the interface
cable
Model name
SFP0602000P-PSE
Accessories:
conversion plug
Voltage range
AC 90 ~ 265 V
Input
Supply current
0.5 A (max)
Voltage range
5.7 ~ 6.3 V
External Power
Supp
ly
Output
Maximum
current
2.0 A (max)