![Opticon OPI-3601 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/opticon/opi-3601/opi-3601_specification-manual_1642022015.webp)
OPI-3601
Specifications Manual
9
7. Technical Specifications
Aim the laser light at the center of a code to scan it. For long distance scanning, ambient light entering
the angle of view may affect the scanning performance. The conditions for technical specifications are
as follows, unless otherwise specified in each section.
<Conditions>
Ambient Temperature and Humidity
Room temperature, room humidity
Ambient Light
100 ~200 lux (on the surface of a bar code)
Angles Pitch:
α
= 0°, Skew:
β
= 15°, Tilt:
γ
= 0°
Curvature R
=
∞
Power Supply Voltage
5.0 V
PCS (1D and 2D)
0.9 or higher
Scanning Test
Accept the performance with 70% or more success rate
for 10 tries of scan. One reading should be 2 seconds.
Barcode Test Sample (1D and 2D)
Specified below.
< Test chart >
For 1D codes, OPTOELECTRONICS test samples
For GS1 Databar, stacked codes and 2D codes, printed by a dedicated printer for bar code