Opticon
C37
Specifications Manual
30
13. Durability
13.1. Power Line Noise
Immunity: ± 1kV and higher
Conditions
Measurement
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance: 330
Ω
Capacitor charging:
150 pF
13.2. Static Electricity
Air discharge (No malfunction): ±10 kV max.
Air discharge (No destruction): ±15 kV max.
Direct discharge (No malfunction): ±10 kV max.
Direct discharge (No destruction): ±15 kV max.
Contact discharge: ±6kV max.
Conditions
Measurement
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Built up and discharged 15 kV of static electricity on the
scanner surface 50 times.
Discharge resistance: 330
Ω
Capacitor charging:
150 pF