Opticon
C37
Specifications Manual
14
7.4.2.
Skew Angle and Dead Zone
Scanning performance is guaranteed when skew angle:
β
≤
±70° (Excluding dead
zone)
Dead zone:
β
= ±20° (There are some areas in which decoding fails due to
specular reflection)
Β
1
=
Β
2
=
0°
Figure 5: Skew angle and dead zone
7.4.3.
Tilt Angle
Scanning performance is guaranteed when
γ
≤
±25°
γ
γ
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Angles:
Pitch angle:
Skew angle:
β
= +0°, Tilt angle:
γ
= 0°
Tilt angle:
Pitch angle:
α
= 0°, Skew angle:
β
= +0°
Skew angle, Dead zone
: Pitch angle:
α
= 0°, Tilt angle:
γ
= 0°
Curvature: R
=
∞