C H A P T E R 7 : O P T I O N S F O R A D V A N C E D U S E R S
41
EV_MFRn_9_ STOPPED - MF digit 9 previously detected, now
stopped.
EV_MFRn_10_ STOPPED - MF digit 10 previously detected, now
stopped.
EV_MFRn_11_ STOPPED - MF digit 11 previously detected, now
stopped.
EV_MFRn_12_ STOPPED - MF digit 12 previously detected, now
stopped.
EV_MFRn_13_ STOPPED - MF digit 13 previously detected, now
stopped.
EV_MFRn_14_ STOPPED - MF digit 14 previously detected, now
stopped.
EV_MFRn_15_ STOPPED - MF digit 15 previously detected, now
stopped.
EV_END_OF_MF_DIGIT - User dialed an MF number and no more
dialed number digits are available. (They have
already been sent. For example, the far side
requests the next ANI digit, but all digits have
been already sent). This event usually appears
in MFR2 tables.
EV_NO_ANI
- User dialed an MF number and no ANI was
specified by the outgoing subscriber. (MFC-R2
protocols specifications should define what to
do when no ANI digits are available. Usually
I-12 is sent).
Note:
MF digit is MF R1 or R2-FWD or R2-BWD according to the
context, protocol type and call direction.
EV_ACCEPT
- When the user accepts a call (used
only in MFC-R2) with CALLED_IDLE
as its reason parameter.
EV_REJECT_BUSY
- When the user rejects a call with
CALLED_BUSY as its reason
parameter.
EV_REJECT_CONGESTION
- User rejects a call with
CALLED_CONGESTION as its reason
parameter.