C H A P T E R 3 : S E T U P O F T H E E 1 / T 1 B O A R D P A R A M E T E R S
15
Source Phone Number
– Enter a string representing the phone number of
the source (origin).
Source Phone SubNumber
- Enter a string representing the phone sub-
number of the source (origin).
Transfer Capability
– Table 3.6 shows the parameter values for the transfer
Capability when ISDN is used. Table 3.7 lists the values for the BC (Bearer
Capability) and the optional HLC (Higher Layer Capability).
In the case of MFC-R2 protocols, you find in Table 3.8 the parameter values
for the service category which is also selected from the Transfer Capability
control.
Not Included
Voice Service
Data Service
Modem Service
Audio 7 Service
Table 3.6: Parameter values for the Transfer Capability in the case of ISDN.
Voice Service
BC= speech, HLC= telephony
Data Service
BC= data
Modem Service
BC= 3.1 kHz audio, HLC= telephony
Audio 7 Service
BC= 7 kHz audio
Table 3.7: The meaning of the Transfer Capability parameter values for ISDN. BC is the Bearer
Capability and HLC represents the Higher Layer Capability.
MFRn_1
MFRn_2
MFRn_3
MFRn_4
MFRn_5
MFRn_6
MFRn_7
MFRn_8
MFRn_9
MFRn_10
MFRn_11
MFRn_12
MFRn_13
MFRn_14
MFRn_15
Table 3.8: Parameter values for the Transfer Capability in the case of MFC-R2 protocols. The list
represents the service category.
InterExchangePrefixNum
– Enter a string representing the Inter Exchange
Prefix Phone Number.
B-Channel Selection
– Table 3.9 lists the parameter values for the B-Channel
Selection parameter .
Any B-channel selection
Preferred selection
Exclusive selection of the B-channel