Weir-Jones Engineering Consultants Ltd.

1

 

 

 

 

 

 

 

30144-REP-001-0.wp9

1.0

INTRODUCTION

On June 10 , 2005 Weir-Jones Engineering Consultants Ltd. (WJEC) was retained by

th

Opticom Technologies Inc. to perform a set of vibration tests on its Model CC-02-4.3 CCTV camera.
The primary objective in testing the camera was to verify its structural integrity.  This was done by
subjecting the unit to the worst-case vibrational stresses expected in its application environment.

The testing consisted of vibrating the Model CC-02-4.3 CCTV camera in the two mutually

perpendicular axes in accordance with the profiles defined in Sections 4.9 of the SAE J1455 (August
1994) Standard and Method 514.5 of the MIL-STD-810F (January 2000) Standard.  The testing of
the camera was performed on June 14  and 15 , 2005.

th

th

2.0

VIBRATION PROFILES

The vibration testing of the Model CC-02-4.3 CCTV camera comprised of subjecting the unit

to the Sinusoidal profile as defined in Section 4.9 of the SAE J1455 (August 1994) Standard and to
the Random profile as defined in Method 514.5 of the MIL-STD-810F (January 2000) Standard.  The
parameters of the Sinusoidal and Random profiles are summarized below with the graphical
representation of the Sinusoidal profile shown in Figure 1 and that of the Random profile shown in
Figure 2.

Sinusoidal (truck chassis-mounted)

Amplitude

*

-

2 G’s from 10 to 12 Hz
2.5 G’s from 12 to 14 Hz
3 G’s from 14 to 16 Hz
3.5 G’s from 16 to 18 Hz
4 G’s from 18 to 2,000 Hz

Sweep rate

-

0.5 octave per minute

Duration

-

180 minutes per axis for each axis.  Unit to be operational as
intended during testing.

*

 the step function is intended to simulate the ramp-up from 10 to 20 Hz.

Random (Basic Transportation for U.S. Highway Truck)

Breakpoints

 - as per Figure 514.5C-1

10 Hz

ÿ

 0.015 G /Hz

2

40 Hz

ÿ

 0.015 G /Hz

2

500 Hz

ÿ

 0.00015 G /Hz

2

RMS

Overall G

 level of 1.04

Duration

-

60 minutes is equivalent to 1,000 miles of travel.  Unit is
recommended to be operational as intended during testing.

Содержание CC-02-4.3

Страница 1: ...Testing of Model CC 02 4 3 CCTV Camera Prepared by Weir Jones Engineering Consultants Ltd 2040 West 10th Avenue Vancouver B C V6J 2B3 Tel 604 732 8821 Fax 604 732 4801 E mail wjgroup weir jones com We...

Страница 2: ...P 001 0 wp9 AUTHORIZATION The work described in this report was authorized by David Boyd of Opticom Technologies Inc on June10 2005 The report was prepared by Paul Chong P Eng th Paul Chong P Eng Proj...

Страница 3: ...CONTENTS 1 0 INTRODUCTION 1 2 0 VIBRATION PROFILES 1 3 0 VIBRATION TEST EQUIPMENT 3 4 0 RESULTS 5 4 1 Sinusoidal Vibration Test 5 4 2 Random Vibration Test 5 APPENDIX 1 Calibration Certificates 7 APPE...

Страница 4: ...subjectingtheunit to the Sinusoidal profile as defined in Section 4 9 of the SAE J1455 August 1994 Standard and to theRandomprofileasdefinedinMethod514 5oftheMIL STD 810F January2000 Standard The par...

Страница 5: ...hical plot of the SAE J1455 Sinusoidal vibration profile intended for equipment to be mounted on truck chassis Blue Vibration profile Red Upper and lower limits of frequency and amplitude equivalent t...

Страница 6: ...rms Random Maximum Payload 220 lbs total weight Driven by LDS PA2000 2kW power amplifier Controlled by LDS DVC 4000 Mk3 Accelerometer Manufacturer PCB Model J357B01 charge capacitance type Serial 8968...

Страница 7: ...direction only a set of Aluminum mounting fixtures were used to position the CCTV camera in its two mutually perpendicular axes Vertical and Transverse as shown in Figures 4A and 4B Feedback accelero...

Страница 8: ...bration tests the camera was therefore subjected to the same vibration profiles as those generated by the shaker The following observations with respect to the CCTV camera were made during and after t...

Страница 9: ...camera was therefore subjected to the same vibration profiles as those generated by the shaker The following observations with respect to the CCTV camera were made during and after the tests No physic...

Страница 10: ...Weir Jones Engineering Consultants Ltd 7 30144 REP 001 0 wp9 APPENDIX 1 Calibration Certificates...

Страница 11: ...Weir Jones Engineering Consultants Ltd 8 30144 REP 001 0 wp9...

Страница 12: ...Weir Jones Engineering Consultants Ltd 9 30144 REP 001 0 wp9...

Страница 13: ...Weir Jones Engineering Consultants Ltd 10 30144 REP 001 0 wp9...

Страница 14: ...Weir Jones Engineering Consultants Ltd 11 30144 REP 001 0 wp9...

Страница 15: ...Weir Jones Engineering Consultants Ltd 12 30144 REP 001 0 wp9 APPENDIX 2 Sinusoidal Test Results...

Страница 16: ...A2 1 Graphical profiles of the Sinusoidal vibration test for the Model CC 02 4 3 CCTV camera mounted in the Vertical orientation Figure A2 2 Graphical profiles of the Sinusoidal vibration test for th...

Страница 17: ...Weir Jones Engineering Consultants Ltd 14 30144 REP 001 0 wp9 APPENDIX 3 Random Test Results...

Страница 18: ...n It should be noted that the amplitude between 10 and 20 Hz had been increased slightly in order to compensate for the lighter weight aluminum fixture The resultant shaker output however still matche...

Отзывы: