background image

 

OPTICAL SYSTEMS DESIGN 

 

 

OSD1250 OPERATOR MANUAL

 

 

PAGE 14  

DOC ID: 10106110 

 

2.9

 

OSD1250 INDICATORS 

 
 
 
 
 
 
 
 
 
 
 
 

FIGURE 5: LED FRONT PANEL INDICATORS. 

 
 

LED No 

LABEL 

LED 
COLOUR 

FUNCTION 

CH 1 

CH 2 

11 

Rx LOS 

Green 

Optical signal is received 

Red 

Loss of Optical Signal 

12 

Link OK 

Green 

Receiver Data Link is locked onto data frame 

Flashing 

Next slave does not detect master in network, bus or fault 

Red 

Data Link frame not locked 

13 

Laser OK 

Green 

Laser function is OK 

Red 

Laser function is not working correctly  

RxD 

Orange 

Receiving from fiber channel and transmitting to copper 

Off 

Not receiving User Data 

Bit Error 

Red 

Receiver is detecting bit errors in Data Link frame 

Off 

No bit errors are present. 

10 

Slave TxC 

Red 

Receiver Link OK is false or Loss of Optical Signal 

Off 

When set as a Master or as Slave and repeating User Data 

TxD 

Orange 

Optical data is transmitted to fiber from copper 

Off 

No data is being transmitted to fiber 

 

TABLE 4: LED INDICATOR FUNCTIONS 

 

 

 

10 

11 

12 

13 

Содержание OSD1250

Страница 1: ...OPERATOR MANUAL OSD1250 SELF HEALING RING DUPLEX DATA TRANSCEIVER...

Страница 2: ......

Страница 3: ...BLE CONNECTION 12 2 8 OPTICAL POWER LEVELS 13 2 9 OSD1250 INDICATORS 14 3 MAINTENANCE 16 3 1 EXTERNAL INSPECTION 16 3 2 ROUTINE MAINTENANCE 16 4 WARRANTY 17 4 1 WARRANTY PERIOD 17 4 2 REPAIRS 17 4 2 2...

Страница 4: ...based system can have as many modems in series as required to cover all likely situations Each OSD1250 within a network monitors the status of adjacent units to determine the health of the network Thi...

Страница 5: ...anti streaming or anti jabber circuits which inhibit transmission if the preset time limit of 300ms is exceeded and then enable transmission after the streaming signal is removed The OSD1250 removes a...

Страница 6: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 6 DOC ID 10106110 FIGURE 1 BASIC BLOCK DIAGRAM...

Страница 7: ...g on each mode Output signals from the interface like DSR are only true if the OSD1250 links are operational The Net Error signal has been included to indicate a Link failure It can be used to energis...

Страница 8: ...Bm Receive Saturation 5dBm Receiver Fail Indication 39dBm to 41dBm Indicators Copper Transmit Data Present Amber 1 Only Receiver Optical Signal Ok Green Red 2 1 per port Receiver Sync Ok Green Red 2 1...

Страница 9: ...is ready for immediate operation However it is advisable to check for external transportation damage before operation If damage is present return the unit and packing to the supplier immediately 2 1...

Страница 10: ...4 WIRE AS REQUIRED OFF ON TABLE 2 SWITCH SETTINGS 2 3 POWER IN CONNECTION Units are powered by 9V to 30VDC 6VA FIGURE 3 POWER IN CONNECTION WARNING Ensure that you are using the correct voltage The u...

Страница 11: ...XD2 3 RTS2 4 CTS2 5 DSR2 6 GND PIN 7 7 7 7 7 DCD2 8 DSR 9 485_4WR DTR 11 DTR 12 485_2W 13 TX 13 13 TX RXD 14 RX 14 RX RTS 15 CTS 16 DCD 17 DSR 18 485_4WR DTR2 20 485_2W 21 TX 21 21 TX RXD 22 RX 22 RX...

Страница 12: ...lable multimode and singlemode optical fibers Remove the protective caps from the optical output and optical input ports Before inserting the optical connectors ensure they are free from any contamina...

Страница 13: ...f equipment Areas where laser products are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area Protective covers should be...

Страница 14: ...locked 3 13 Laser OK Green Laser function is OK Red Laser function is not working correctly 4 8 RxD Orange Receiving from fiber channel and transmitting to copper Off Not receiving User Data 5 9 Bit...

Страница 15: ...250 MASTER INTERFACE CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 1 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 2 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 3 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 3...

Страница 16: ...efully Some components are extremely expensive and can be damaged by failure of any part of their support circuitry 3 1 EXTERNAL INSPECTION Visually check the following Inspect the optical connectors...

Страница 17: ...ve for all repairs 4 2 2 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the...

Страница 18: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 18 DOC ID 10106110...

Страница 19: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 19 DOC ID 10106110...

Страница 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Отзывы: