background image

 

OPTICAL SYSTEMS DESIGN 

 

 

OSD1250 OPERATOR MANUAL

 

 

PAGE 12  

DOC ID: 10106110 

 

2.5

 

ALARMS 

 
The OSD1250 has an open drain MOSFET rated at 200mA @ 50V max on pin 26 of the DB26 connector. Output at pin26 is 
0Ω when unit is powered and ring/bus fiber link present. The output at pin26 becomes high impedance on all units on ring/bus 
when any fiber link is broken or the unit is off along the ring/bus. The output can be connected to a relay coil as shown. 
 
 
 
 
 
 
 
 
 
 

FIGURE 4: CONTACT CLOSURE OUTPUT 

 

 

2.7

 

FIBER OPTIC CABLE CONNECTION 

  
The OSD1250 supports all commonly available multimode and singlemode optical fibers. Remove the protective caps from the 
optical output and optical input ports. 
  
Before inserting the optical connectors ensure they are free from any contamination.  If they need cleaning use alcohol and lint 
free  tissues.    Connect  the  already  terminated  cables  to  the  output/input  ports.    Ensure  that  the  optical  output  port  of  one 
OSD1250 connects to the optical input port of an OSD1250 at the other end. 
  
Remember  that  the  optical  transmit  channel  of  one  modem  connects  to  the  optical  receive  channel  of  the  next  unit  of  the 
system and vice versa. 
  
Figure 6 shows the set up for a typical bus configured system and Figure 7 shows a typical ring configured system. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DB26 
Pin26 

OSD1250 

50V

(max) 

External 

Relay

 

Содержание OSD1250

Страница 1: ...OPERATOR MANUAL OSD1250 SELF HEALING RING DUPLEX DATA TRANSCEIVER...

Страница 2: ......

Страница 3: ...BLE CONNECTION 12 2 8 OPTICAL POWER LEVELS 13 2 9 OSD1250 INDICATORS 14 3 MAINTENANCE 16 3 1 EXTERNAL INSPECTION 16 3 2 ROUTINE MAINTENANCE 16 4 WARRANTY 17 4 1 WARRANTY PERIOD 17 4 2 REPAIRS 17 4 2 2...

Страница 4: ...based system can have as many modems in series as required to cover all likely situations Each OSD1250 within a network monitors the status of adjacent units to determine the health of the network Thi...

Страница 5: ...anti streaming or anti jabber circuits which inhibit transmission if the preset time limit of 300ms is exceeded and then enable transmission after the streaming signal is removed The OSD1250 removes a...

Страница 6: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 6 DOC ID 10106110 FIGURE 1 BASIC BLOCK DIAGRAM...

Страница 7: ...g on each mode Output signals from the interface like DSR are only true if the OSD1250 links are operational The Net Error signal has been included to indicate a Link failure It can be used to energis...

Страница 8: ...Bm Receive Saturation 5dBm Receiver Fail Indication 39dBm to 41dBm Indicators Copper Transmit Data Present Amber 1 Only Receiver Optical Signal Ok Green Red 2 1 per port Receiver Sync Ok Green Red 2 1...

Страница 9: ...is ready for immediate operation However it is advisable to check for external transportation damage before operation If damage is present return the unit and packing to the supplier immediately 2 1...

Страница 10: ...4 WIRE AS REQUIRED OFF ON TABLE 2 SWITCH SETTINGS 2 3 POWER IN CONNECTION Units are powered by 9V to 30VDC 6VA FIGURE 3 POWER IN CONNECTION WARNING Ensure that you are using the correct voltage The u...

Страница 11: ...XD2 3 RTS2 4 CTS2 5 DSR2 6 GND PIN 7 7 7 7 7 DCD2 8 DSR 9 485_4WR DTR 11 DTR 12 485_2W 13 TX 13 13 TX RXD 14 RX 14 RX RTS 15 CTS 16 DCD 17 DSR 18 485_4WR DTR2 20 485_2W 21 TX 21 21 TX RXD 22 RX 22 RX...

Страница 12: ...lable multimode and singlemode optical fibers Remove the protective caps from the optical output and optical input ports Before inserting the optical connectors ensure they are free from any contamina...

Страница 13: ...f equipment Areas where laser products are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area Protective covers should be...

Страница 14: ...locked 3 13 Laser OK Green Laser function is OK Red Laser function is not working correctly 4 8 RxD Orange Receiving from fiber channel and transmitting to copper Off Not receiving User Data 5 9 Bit...

Страница 15: ...250 MASTER INTERFACE CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 1 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 2 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 3 CH 1 CH 2 TX RX TX RX 1250 SLAVE INTERFACE 3...

Страница 16: ...efully Some components are extremely expensive and can be damaged by failure of any part of their support circuitry 3 1 EXTERNAL INSPECTION Visually check the following Inspect the optical connectors...

Страница 17: ...ve for all repairs 4 2 2 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the...

Страница 18: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 18 DOC ID 10106110...

Страница 19: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 19 DOC ID 10106110...

Страница 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Отзывы: