OPTICAL SYSTEMS DESIGN
OSD1250 OPERATOR MANUAL
PAGE 10
DOC ID: 10106110
2.2
SWITCH SETTINGS
In the context of the following switch settings for the module version the ON position is UP and the OFF position is down.
The term AS refers to Anti-Streaming.
The BIAS switch SW2 is dual function and only generates BIAS in RS485 modes.
MODE
SW1
SW2
SW3
SW4
RS485 BIAS
MASTER
ON
SLAVE
OFF
RS232 WITH AS
OFF
OFF
OFF
RS422 WITH AS
OFF
OFF
OFF
RS232/422 NO AS
ON
ON
OFF
RS485 2 WIRE
AS REQUIRED
ON
ON
RS485 4 WIRE
AS REQUIRED
OFF
ON
TABLE 2: SWITCH SETTINGS
2.3
POWER IN CONNECTION
Units are powered by +9V to 30V
DC
@ 6VA.
FIGURE 3: POWER IN CONNECTION
WARNING - Ensure that you are using the correct voltage!
The unit employs an internal resetable solid state fuse to protect both it and the power source in the event of a fault in the
modem’s internal power supply.
The OSD1250 card version requires DC power which is connected via a DB9 connector and supplied by the OSD370N or
OSD350N chassis. The card should be fixed into the chassis using the captivated screws. The cards can be plugged in or out of
the chassis with power on or off.
1
2
3
4
5
6
7
8
9
10
11
12
13
A
B
C
D
E
Negative Input
Positive Input
Содержание OSD1250
Страница 1: ...OPERATOR MANUAL OSD1250 SELF HEALING RING DUPLEX DATA TRANSCEIVER...
Страница 2: ......
Страница 6: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 6 DOC ID 10106110 FIGURE 1 BASIC BLOCK DIAGRAM...
Страница 18: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 18 DOC ID 10106110...
Страница 19: ...OPTICAL SYSTEMS DESIGN OSD1250 OPERATOR MANUAL PAGE 19 DOC ID 10106110...