Rear Panel 

 

 

                 

 

         PS500C/700C 110/120V 

 

 

                   

 

PS500C/700C 230/240V 

 

n
o

q

s
r

 

p

n
o

 

r

 

s
p

 

q

 

 

 

 

3

n

 REMOTE PORT 

Provide both RS-232 and relay signal or USB to support NOVELL, UNIX, DOS, 
WINDOWS and other operating systems. 

o

 TEL./MODEM protection   

Telecom transfer ports provide users to extend the applications. 

Caution:

 To reduce the risk of fire, use only No. 26AWG or larger telecommunication line 

cord. 

p

 AC INPUT POWER RECEPTACLE 

The input power cord needs to connect the rear inlet socket of the UPS and plug into a 
socket on the wall. Please notice the voltage of utility power should match with the UPS. For 
example, the rating voltage of UPS is 110V/(220V), the input utility power should be the 
same as 110V/(220V). 

q

 INPUT CIRCUIT BREAKER/ FUSE 

It trips when the connected loads exceed the protected receptacle‘s capacity. The center 
plungers of the circuit breakers/ fuse enabled when tripped. 

r

 UPS OUTLETS   

When utility power is normal, the UPS outlets are powered by utility power without AVR 
function. Any higher or lower utility power would be rectified by AVR function. When 
utility power is fail, the UPS outlets are powered from battery. 

s

 CONVENIENCE OUTLET 

The CONVENIENCE outlet is pass from the utility power with voltage spike filtering 
function. 

Содержание Power PS500C

Страница 1: ...User Guide Power Series Models PS500C PS700C ...

Страница 2: ... in a fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of electric shoc...

Страница 3: ...ode if none of the connected loads is operating Advanced battery management The visual and audible indications of the UPS present the battery s status including capacity degree and battery condition Self test function let UPS detect a weak battery before it is put into service The UPS normally perform a self test at power up and manual self test condition Self test function can be conducted manual...

Страница 4: ...ll Please notice the voltage of utility power should match with the UPS For example the rating voltage of UPS is 110V 220V the input utility power should be the same as 110V 220V q INPUT CIRCUIT BREAKER FUSE It trips when the connected loads exceed the protected receptacle s capacity The center plungers of the circuit breakers fuse enabled when tripped r UPS OUTLETS When utility power is normal th...

Страница 5: ...ly to indicate overload status UPS will shut down automatically to protect the machine Attention If the power of UPS isn t supplied by utility but by the internal batteries to engage the UPS press the ON TEST button and keep pressing for over 2 seconds 3 2 Switch off By pressing and holding OFF button until the LINE NORMAL or BACK UP LED off 3 3 Silence When UPS is under BACKUP mode press ON TEST ...

Страница 6: ...um rated capacity the UPS will emit continuous alarm to warn an overload condition In order to protect the unit and the loads the UPS will be automatic shutdown Disconnect nonessential devices from UPS to eliminate the overload alarm 7 5 Software installation and Interface Port 5 1 Power Monitoring Software The SENTINEL series software or other power monitoring software is applied standard RS 232 ...

Страница 7: ... authorized UPS monitoring cable 9 5 4 The characteristics of software SENTINEL The communication port on the back of the UPS may be connected to host computer Through utilizing SENTINEL software the computer is allowed monitor the status of the UPS and control the operation of the UPS in some cases Its major functions normally include some or all of the following z To broadcast a warning when pow...

Страница 8: ...on intake open 6 1 6 Avoid direct sunlight rain and high humidity 6 1 7 Stay away from fire and extremely hot location 6 1 8 Do not stack materials on top of the unit 6 1 9 The unit should not be exposed to corrosive air 6 1 10 The normal operating temperature is 0 40 6 2 Storage conditions Store the UPS covered and upright in a cool and dry location with its battery fully charged Before storing c...

Страница 9: ...hey are well connected If there is any damage on battery packs replace new ones ASAP 13 Appendix B Specifications Model PS500C PS700C Capacity 500VA 300W 700VA 420W Voltage 110V 120V 220V 230V 240V Input Frequency 50 or 60Hz 10 auto sensing Voltage on battery Pure sine wave output at nominal 5 Frequency on battery 50 or 60Hz 0 5 Output Voltage Regulation AVR AVR automatically increase output volta...

Отзывы: