background image

-11-

SPECIFICATIONS

11

* Specifications and design are subject to change without prior notice.

Model

Detection method

PIR Coverange

Distance limit

Detectable speed

Sensitivity

Power input

Current draw

Alarm period

Warm-up period

Alarm output

Tamper output

Trouble output

Aux input

LED indicator

RF Interference

Operating temperature

Environment humidity

Weatherproof

Mounting

Mounting height

Bracket adjust angle

Weight

Accessories

HX-40

HX-40 AM

Passive infrared

12 m (40 ft.) 85° wide / 94 zones

4 m, 5.5 m, 9 m, 12 m (13 ft, 18 ft, 30 ft, 40 ft.)

0.3 – 1.5 m/s (1 – 5 ft/s)

2.0°C (3.6°F) at 0.6 m/s

9.5 – 18VDC

35 mA (max) at 12VDC

40 mA (max) at 12VDC

2.0 ± 1 sec

Approx. 60 sec(LED blinks)

Form C 28VDC 0.2A max

N.C. 28V DC, 0.1A max

N.C. 28V DC, 0.1A max

N.C. 28V DC, 0.1A max

Red:Warm-up, Alarm

Red:Warm-up, Alarm, Trouble

No alarm 10 V/m

-20 – +60°C (-4 – +140°F)

95% max

IP55

Wall (Outdoor, Indoor)

2.5 - 3.0 m (8.3 - 10 ft.)

Vertical: ± 20° Horizon: ± 95°

600 g (21.2 oz)

Bracket, Hood, Area masking seal, Screw kit (3×10-2, 4×20-4)

Содержание HX-40/40AM

Страница 1: ...h two PIRs HX 40AM HX 40 with IR anti masking feature HX 40 40AM HX 40 40AM Warning Warning Caution INSTALLATION HINTS 1 1 INSTALLATION HINTS 1 2 PARTS IDENTIFICATION 2 3 KNOCKOUTS 2 4 DETECTION AREA...

Страница 2: ...masking infrared LED HX 40AM only For wall fastening Wiring Hole Wiring Hole Off the shelf magnet switch installation position Adjustment screw For switch box fastening For main unit fastening Up dow...

Страница 3: ...DETECTION AREA SETTING 4 4 B Detection Length Adjustment 4 A Detection Area Top view of detection area 90 4 0 3 0 2 0 10 0 8 m 26 7ft 8 m 26 7ft 12 m 40 ft 12 m 40 ft 3 0 m 10 ft 12 m 40 ft 2 5 m 8 3...

Страница 4: ...ugh the base knockout and install the base on the bracket Adjustment screw BRACKET INSTALLATION AND ADJUSTMENT 6 20 20 90 90 6 A Bracket installation Shaft cover Push Using the bracket makes it possib...

Страница 5: ...astened to the bracket you can not remove the shaft cover Caution 9 6 B Detection distance check and up down angle adjustment Adjustment screw The LED lights when you come closer within 9 m 30 ft Adju...

Страница 6: ...NC COM NO SP SP AUX INPUT ALARM POWER 9 5 18VDC WIRING 7 1 TAMPER terminals to be connected to a 24 hour supervisory loop HX 40AM HX 40 SPARE Non short ALARM OUTPUT N O ALARM OUTPUT COM ALARM OUTPUT N...

Страница 7: ...OR 8 A 8 B 8 C 8 D 8 E Do not touch NOTE For the walk test move more than 1 m 0 3 ft away from the detector AND factory default POSITION FUNCTION OR When both the Main unit and the satellite detect so...

Страница 8: ...anti masking signal When an object is placed close to the lens surface for a period of more than 180 seconds the IR Anti Masking circuit will activate and generate a trouble signal LED Operation DETE...

Страница 9: ...etween the moving object and the background For example when the detection distance is set to 12 m 40 ft sometimes vehicles 13 m 43 ft away may be detected In this case set the detection distance to 9...

Страница 10: ...1 2 3 4 5 6 7 8 9 0 1 9 2 8 3 7 4 6 5 56 HX 40AM HX 40 LED FUNCTIONS 10 DETECTOR STATUS Alarm Warm up period LED Indication Red light Red blinks LED operation Light Blink OFF Red DETECTOR STATUS Alarm...

Страница 11: ...height Bracket adjust angle Weight Accessories HX 40 HX 40 AM Passive infrared 12 m 40 ft 85 wide 94 zones 4 m 5 5 m 9 m 12 m 13 ft 18 ft 30 ft 40 ft 0 3 1 5 m s 1 5 ft s 2 0 C 3 6 F at 0 6 m s 9 5 1...

Страница 12: ...www optexamerica com OPTEX KOREA CO LTD KOREA TEL 82 2 719 5971 URL http www optexkorea com OPTEX SECURITY Sp z o o POLAND TEL 48 22 598 06 55 URL http www optex com pl OPTEX DONGGUAN CO LTD SHENZHEN...

Отзывы: