background image

-10-

To limit the detection range, apply the area masking seal to the section you want to hide on the
lens inside. Configure the area in such a way as to avoid having anything cut across the area.

9-B

Area Masking

Pasting on example for

masking No. 5 and No. 6

Area masking seal

1
2
3
4
5
6
7
8
9

0

1

9

2

8

3

7

4

6

5

56

HX-40AM

HX-40

LED FUNCTIONS

10

DETECTOR STATUS

Alarm

Warm-up period

LED Indication

Red light

Red blinks

LED operation

Light

Blink

OFF

Red

DETECTOR STATUS

Alarm

Warm-up period

Trouble

output

Anti-Masking booting

(Anti-Masking start up)

Anti-Masking

LED Indication

Red light

Red blinks

Red blinks 2 times and goes off for 5 sec.

This movement is repeated.

Red blinks 3 times and goes off for 3 sec.

This movement is repeated.

LED operation

Содержание HX-40/40AM

Страница 1: ...h two PIRs HX 40AM HX 40 with IR anti masking feature HX 40 40AM HX 40 40AM Warning Warning Caution INSTALLATION HINTS 1 1 INSTALLATION HINTS 1 2 PARTS IDENTIFICATION 2 3 KNOCKOUTS 2 4 DETECTION AREA...

Страница 2: ...masking infrared LED HX 40AM only For wall fastening Wiring Hole Wiring Hole Off the shelf magnet switch installation position Adjustment screw For switch box fastening For main unit fastening Up dow...

Страница 3: ...DETECTION AREA SETTING 4 4 B Detection Length Adjustment 4 A Detection Area Top view of detection area 90 4 0 3 0 2 0 10 0 8 m 26 7ft 8 m 26 7ft 12 m 40 ft 12 m 40 ft 3 0 m 10 ft 12 m 40 ft 2 5 m 8 3...

Страница 4: ...ugh the base knockout and install the base on the bracket Adjustment screw BRACKET INSTALLATION AND ADJUSTMENT 6 20 20 90 90 6 A Bracket installation Shaft cover Push Using the bracket makes it possib...

Страница 5: ...astened to the bracket you can not remove the shaft cover Caution 9 6 B Detection distance check and up down angle adjustment Adjustment screw The LED lights when you come closer within 9 m 30 ft Adju...

Страница 6: ...NC COM NO SP SP AUX INPUT ALARM POWER 9 5 18VDC WIRING 7 1 TAMPER terminals to be connected to a 24 hour supervisory loop HX 40AM HX 40 SPARE Non short ALARM OUTPUT N O ALARM OUTPUT COM ALARM OUTPUT N...

Страница 7: ...OR 8 A 8 B 8 C 8 D 8 E Do not touch NOTE For the walk test move more than 1 m 0 3 ft away from the detector AND factory default POSITION FUNCTION OR When both the Main unit and the satellite detect so...

Страница 8: ...anti masking signal When an object is placed close to the lens surface for a period of more than 180 seconds the IR Anti Masking circuit will activate and generate a trouble signal LED Operation DETE...

Страница 9: ...etween the moving object and the background For example when the detection distance is set to 12 m 40 ft sometimes vehicles 13 m 43 ft away may be detected In this case set the detection distance to 9...

Страница 10: ...1 2 3 4 5 6 7 8 9 0 1 9 2 8 3 7 4 6 5 56 HX 40AM HX 40 LED FUNCTIONS 10 DETECTOR STATUS Alarm Warm up period LED Indication Red light Red blinks LED operation Light Blink OFF Red DETECTOR STATUS Alarm...

Страница 11: ...height Bracket adjust angle Weight Accessories HX 40 HX 40 AM Passive infrared 12 m 40 ft 85 wide 94 zones 4 m 5 5 m 9 m 12 m 13 ft 18 ft 30 ft 40 ft 0 3 1 5 m s 1 5 ft s 2 0 C 3 6 F at 0 6 m s 9 5 1...

Страница 12: ...www optexamerica com OPTEX KOREA CO LTD KOREA TEL 82 2 719 5971 URL http www optexkorea com OPTEX SECURITY Sp z o o POLAND TEL 48 22 598 06 55 URL http www optex com pl OPTEX DONGGUAN CO LTD SHENZHEN...

Отзывы: