background image

11

- Troubleshooting

- Timing chart

PIR detection signal

Detection

Walk test mode

No alarm signal output

Stand-by

Alarm output

LED on

Pulse count 2

10 minutes after power on

< 120 s/5 s

Low power mode

Alarm output

Stand-by

LED off

LED output

LED off

LED off

> 120 s/5 s

[1]

[2]

Problem

Solution

Cause

The LED is off.

The power supply voltage does not meet the requirement 

due to disconnection from the power supply or low voltage.

Incorrect detection area.

The detector is in low power mode.

Check the power supply of the detector. 

Refer to “Specifications” on the page 9 for the power 

supply voltage.
Adjust the detection area. Refer to “Detection area” 

on the page 10.
Power on the detector again if an additional walk test

is needed.

Remove the moving object from the detection area or

change the detector location.
Remove the heat source fron the detection area or

change the detector location.

Check the output load. Repair or replace the 

damaged part.
Connect the wires for the detector correctly.

Be sure that there is no moving object in the detection

area during the warm-up period of the detector.
Repair or replace the detector.

A moving object exsts in the detection area, such as

a fluttering curtain or a swinging wall-mounted pendant.
The temperature changes rapidly in the detection area

due to a heat source, such as a radiator or air conditioner.

Relay contact abhesion or damage occurs due to 

overload.

Improper wiring.

A moving object exista in the detection area during

the warm-up period of the detector.

The detector fails to work properly.

The LED is on even there is no

person in the detection area.

The LED is on but the detector

does not transmit signals.

The detector fails to warm up in

60 seconds after power on and

the LED blinks continuously.

Содержание AP-360BR

Страница 1: ...Specifications Dimensions Detection area Troubleshooting Timing chart Compliance Before installation Others Contents Page 2 3 Installation Ceiling mount without switch box Wiring 2 Ceiling mount with...

Страница 2: ...cause injury and or property damage Check mark indicates recommendation Nix sign indicates prohibition Special attention is required to the section of this symbol Mounting height 2 5 to 4 5 m 8 2 to 1...

Страница 3: ...cations 3 Top cover Lens Base cover JP2 PIR sensitivity JP1 Alarm output mode SW1 Tamper switch Accessories Retaining spring x 2 Fixing screw Mounting Bezel for an 86 type box Screw cap x 2 JP3 Batter...

Страница 4: ...rees to prevent interference with the casing Jumper pin settings Assemble Close the base cover and fasten the screw to fix the cover JP1 Alarm output mode JP2 PIR sensitivity 1 2 3 120 s default 5 s J...

Страница 5: ...retaining spring 1 2 3 Mount the detector on the ceiling Be sure to arrange the wires with a downward slope to prevent water igress into the detector 1 4 2 3 Insert the detector into the hole with th...

Страница 6: ...ccessories used in this installation Mounting Bezel for an 86 type box Screw cap x 2 Options to procure in the market 86 type box x 1 or 2 Screw x 2 1 Prepare an 86 type box on the ceiling Install the...

Страница 7: ...7 2 3 Wiring 1 Red 2 Black 3 White 4 Yellow 5 Green 6 Blue Power supply positice Power supply negative Alarm output Alarm output Tamper output Tamper output Alarm Tamper Transmitter...

Страница 8: ...8 Power on Wait for 60 seconds to complete the warm up time Walk in the detection area to check the detecting performance 3 1 Walk test 3 Checking 1 2 3 Start operation 4 Power 60 sec...

Страница 9: ...tivity Weight Operation temprature Operation humidity Location Dimensions Passive infrared N C 28 V DC 100 mA max The contact opens once the casing is detached Approx 60 s H M L 95 Indoors Model AP 36...

Страница 10: ...2 0 6 7 1 0 3 3 0 1 0 3 3 2 0 6 7 3 0 9 10 Mounting height Detection area Maximum detection area 2 5 8 2 3 3 10 10 3 0 9 10 4 0 13 1 3 5 11 6 4 6 15 1 4 0 13 1 5 4 17 8 4 5 14 9 6 0 20 Unit m ft in 3...

Страница 11: ...ange the detector location Remove the heat source fron the detection area or change the detector location Check the output load Repair or replace the damaged part Connect the wires for the detector co...

Страница 12: ...ww optex europe com nl OPTEX SECURITY SAS France www optex europe com fr OPTEX SECURITY Sp z o o Poland www optex europe com pl OPTEX PINNACLE INDIA PVT LTD India www optexpinnacle com OPTEX KOREA CO...

Отзывы: