41
3-5 Event log recording function
An event log will be generated and stored on the ACCURANCE-3D control box SSD as a video file, in the
following format.
Data Recording will start one second before the door opening and end one second after the output signal is
generated on the A3001CB.
Typically there are 5 to 6 seconds between the door opening and a Zero, One, More or Suspicious output
being activated. (Please see Fig 3-3)
3D image data is stored on the SSD of A3001CB when "Authorization signal" input is received from the
Biometric reader or Authorization device in the Interlock.
When no "Authorization signal” is received, no 3D image data will be recorded.
For example when a person exits the secured area in one way Interlock System, a person doesn't need to
make an Authorization using Biometric reader or Authorization device. In this case A3001CB doesn't make
Piggyback output.
Stored 3D image data can be review using the “Name of Software Viewer provided.
3D image recording
1 sec
Door1
Close
Open
Close
(Activation)
AIR
2 sec
1 sec
Zero
1 sec
One
More
Suspicious
Authorization
Door2
Close
Open Close
Time
Door1
close
Door2
close
Fig 3-3