6
Wiring Diagram
BANK
(1)
(2)
1
OPEN
OPEN
2
CLOSE OPEN
3
OPEN CLOSE
4
CLOSE CLOSE
15 pieces (AWG26)
Dot mark 1
Dot mark 2
No.
Output cable
Descriptions
Line
color
Dot mark
Color Quantity
1
Pink
Red
1
Power supply
12 to 24 VDC
2
Gray
Black
1
GND
3
White
Red
1
Analog output
4-20 mA
+
4
White
Black
1
-
5
Pink
Black
1
External trigger
Input
6
Gray
Black
2
Bank switch
(1)
7
White
Red
2
(2)
8
Yellow
Red
1
Alarm output
H
N.C.
9
Gray
Red
1
COM
10
Yellow Black
1
N.O.
11
Orange
Red
1
Alarm output
L
N.O.
12
Gray
Red
2
COM
13
Orange Black
1
N.C.
14
Orange
Red
2
Do not wire
15
Orange Black
2
Connect to GND
16
*4 (Shielded cable)
-
●
Output cable
*1 Connect to the 4-20 mA input of an analog device.
Analog output allowable load 250Ω and analog output impedance 47 Ω
*2 External trigger: Switches on/off in the range from 2 to 5.
*3 Bank switch: Switches OPEN/CLOSE in the range from 2 to 6 or from 2 to 7 to select a bank.
*2
*3
c contact
300 mA/30 VDC or less
c contact
300 mA/30 VDC or less
Do not wire
Connect to GND
*1
*4 When you cut the output cables shorter, a shielded cable for reinforcement will come out. Cut the
shielded cable to prevent it from contacting with other cables.
* Cables not used should be cut so that they do not contact with other cables, and insulated with
adhesive tape or by other methods.