- 15 -
Connections
5. CONNECTIONS
Before you can make any video and other signal connections, the factory-set IP address and
subnet mask of the C-54 E must be changed to be compatible with the network segment the
module will be used in.
5.1. Establishing a Network Connection
The factory-set IP address of a C-54 E is in the 10.x.x.x range. You will find it printed on a
sticker on the module.
please note
This is the address the module will revert to if you issue a ‘Reset to factory settings; incl.
network settings’ command and reboot the module (see section 7.10.6).
To open communication with the C-54 E from a host PC and change the module’s network
settings, perform the following steps:
Step 1:
Set the PC’s network adapter to the module’s factory default subnet and connect
the two devices (see below for details).
Step 2:
Access the module from a web browser (see section 7.2) or other tool installed
on the PC.
Step 3:
Set the module address and subnet mask to the subnet it will be used in and
reboot the module (see section 7.6).
To address the module from the same PC again, configure the PC’s network adapter once
more to assign the PC to the same subnet as the module.
Figure 5.1 C-54 E product sticker
Factory-set IP address
C-54 E