Section B – Quick Start Guide for Flat-Man XL30 and larger:
NOTE
: Do not plug in the line cord until all other cables are connected.
1.
Carefully unpack the Flat-Man XL. You should have the following parts:
a.
Flat-Man XL lamp panel,
b.
HV Power supply (silver and blue inverter),
c.
Line cord for HV supply,
d.
Flat-Man XL Controller circuit (small black box),
e.
USB cable – 12-ft (4m) length,
f.
Long gray Lamp cable – 2-position XL controller to circular lamp
connector,
g.
Short gray HV cable – 4-pos HV Supply RED connector to 2-pos
controller,
h.
Short gray Control cable – 4-pos XL controller to 4-pin circular locking
connector.
2.
Connect the HV Control cable between the Flat-Man XL Controller (white 4-
position plug) and the HV power supply (large, circular 4-position connector).
This 4-pin Amp connector replaces the small, flat connector visible on the
opposite side of the r HV power supply. NOTE: XL-30 owners of the first
generation Cevanna inverters should use care when releasing the flat 6-pin (4-
contact) tab to disconnect the HV Control cable. Contact Optec for upgrade or
conversion to the 4-pin Amp style connector.