Biopel line – Compressor burner cleaning 10 – 200 kW
6
2
SETUP
You need to select operational times in v8 control unit. To do so follow instructions below.
Installer settings, Compressor:
o
Cleaning period
Interval čištění = 2min
o
Opening time = 2s
o
Cycle time = 30s
o
Interval time = 1 to 15h
Check also Operation control function in Service menu. Go to Service menu, Auger, Work, Operation
control
– set 10s. If there is no flame after compressor cleaning photosensor doesn’t detect the light.
After 10s control unit goes to ignition again automaticly.
Setup in compressor submenu can vary considering different burner sizes. By leaving compressor
deactivated you can say that compressor cleaning will be performed only after extinction, when boiler is
switched off. We recommend to not activate compressor during PID work. Cleaning by compressor
during pid work is good only for high powers such as 100-200kW.