14
Introduction
Perfect Pick User Manual - OPEX Corporation
Ultra-capacitor Product Information
0D[ZHOO7HFKQRORJLHV6$
&+5RVVHQV
6ZLW]HUODQG
3KRQH
)D[
0D[ZHOO7HFKQRORJLHV*PE+
%UXFNHU6WUDVVH
'*LOFKLQJ
*HUPDQ\
3KRQH
)D[
0D[ZHOO7HFKQRORJLHV,QF
:RHDGTXDUWHUV
%DOERD$YHQXH
6DQ'LHJR&$
86$
3KRQH
)D[
LQIR#PD[ZHOOFRP±ZZZPD[ZHOOFRP
0D[ZHOO7HFKQRORJLHV,QF
6KDQJKDL5HSUHVHQWDWLYH2IILFH
5P6XQFRPH/LDXZ¶V3OD]D
6KDQJ&KHQJ5RDG
3XGRQJ1HZ$UHD
6KDQJKDL35&KLQD
3KRQH
)D[
Document #1004596.4
Product Information Sheet
An MSDS is not required. This information sheet is provided as a service to our customers. An MSDS for the active chemical inside the listed products is
available upon request.
For US Customers:
The products referenced herein are exempt articles and are not subject to the OSHA Hazard
Communications Standard Requirement 29 CFR 1910.1200.
For EU Customers:
The products referenced herein are not submitted to 91-155 EEC, as
they are considered as components and not as a chemical substance.
Notice
: The information and recommendations herein contained are made in good
faith and are believed to be accurate at the date of preparation. Maxwell Technologies Inc. makes no warranty expressed or implied.
Product Information
Manufacturer
Maxwell Technologies Inc.
9244 Balboa Avenue San Diego, CA 92123
Phone: 858-503-3300
Fax: 858-503-3333
EMERGENCY PHONE:
North America
Chemtrec Hazmat Communication Center 1 800 424 9300
+ 1 703 527 3887
Europe
Swiss Toxicological Information Centre
+41 (0)44 251 5151
Product:
Ultracapacitors
Models:
All configurations and versions of
PC5, PC10, PC5-5, BCAP0005 and
BCAP0010
Date:
June 19, 2009
Asia
Chemtrec Hazmat Communication Center 1 800 424 9300
+ 1 703 527 3887
Product Components
Important Safety Note
: Ultracapacitors should not be opened, disassembled, crushed, burned, or exposed to high temperatures (>85°C, 185°F), and
should be operated only within their defined operating specifications. Failure to adhere to operating specifications could result in poor device
performance or unsafe operating conditions. Exposure to the components contained within the ultracapacitor could be harmful under certain
circumstances. In case of exposure to ultracapacitor contents, wash affected area for at least 15 minutes with generous amounts of water and seek medical
attention. Fires involving these types of ultracapacitors should be extinguished with CO2, dry chemical, alcohol foam, or all purpose AFFF extinguishing
media. Water may be ineffective but should be used to cool fire-exposed containers, structures and to protect personnel.
BOOSTCAP® ultracapacitors are composed of the following major components:
Electrodes:
Activated
Carbon
Separator:
Polypropylene or Cellulose
Electrolyte:
Quaternary salt (tetraethylammonium tetraflouroborate)
Organic
solvent
(acetonitrile)
Other:
Aluminum,
steel
Disposal
BOOSTCAP ultracapacitors are neither specifically listed nor exempted from government hazardous waste regulations. The only material
of possible concern is the organic solvent, which when discarded or disposed of, is a hazardous waste according to Federal regulations (40
CFR 261). It is listed as Hazardous Waste Number U003, so listed due to its toxicity and ignitability. Disposal can occur only in properly
permitted facilities. Check state and local regulations for any additional requirements, as these may be more restrictive than federal laws
and regulations.
Transportation
Ultracapacitors as articles are not specifically listed nor exempted from hazardous materials regulations (HMR). The U.S. Department of
Transportation has provided Maxwell Technologies a written determination regarding Maxwell’s PC5 and PC10 BOOSTCAP
ultracapacitor products that the materials comprising the ultracapacitors are “…in a quantity and form that does not pose a hazard in
transportation. Therefore, the ultracapacitors are not subject to the HMR.”