background image

S li m   M e di cal   P a n el   P C 

O N Y X - 1 2 2

 

 

 

Below Table for China RoHS Requirements 

產品中有毒有害物質或元素名稱及含量

 

Onyx Panel PC/ Workstation   

有毒有害物質或元素

 

部件名稱

 

 

(Pb)

 

(Hg)

 

(Cd)

六價鉻

(Cr(VI))

多溴聯苯

(PBB) 

多溴二苯醚

(PBDE) 

印刷電路板

 

及其電子元件

 

× 

 

 

 

 

 

外部信號

 

連接器及線材

 

× 

 

 

 

 

 

外殼

 

× 

 

 

 

 

 

中央處理器

 

與記憶體

 

× 

 

 

 

 

 

硬碟

 

× 

 

 

 

 

 

液晶模組

 

× 

 

 

 

 

 

光碟機

 

× 

 

 

 

 

 

觸控模組

 

× 

 

 

 

 

 

電源

 

× 

 

 

 

 

 

 

 

 

 

 

 

 

O

表示該有毒有害物質在該部件所有均質材料中的含量均在

 

SJ/T 11363-2006

標準規定的限量要求以下。

 

X

:表示該有毒有害物質至少在該部件的某一均質材料中的含量超出

 

SJ/T 11363-2006

標準規定的限量要求。

 

備註:

 

一、此產品所標示之環保使用期限,系指在一般正常使用狀況下。

 

二、上述部件物質中央處理器、記憶體、硬碟、光碟機、觸控模組為選購品。

 

Содержание ONYX-122

Страница 1: ...Slim Medical Panel PC O N Y X 1 2 2 ONYX 122 11 6 Intel CoreTM 2 Duo Processor High Brightness Slim Medical Panel PC ONYX 122 Manual 1 st Edition Nov 2010 ...

Страница 2: ...s intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy...

Страница 3: ...es Corporation Microsoft Windows is a registered trademark of Microsoft Corporation RTL is a trademark of Realtek Semi Conductor Co Ltd C T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporation ITE is a trademark of Integrated Technology Express Inc All other product names or trademarks are properties of their respective owners ...

Страница 4: ...NYX 122 CD ROM into external CD ROM drive which Contains User s Manual in PDF format Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Lane 235 Pao Chiao Rd Hsin Tien City Taipei 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com...

Страница 5: ...srijt 4002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 49 0 61033 7479 49 Onyx Healthcare SU ZHOU INC Room 12 2F Building B No 5 Xing Han Street Suzhou Industrial Park Jiang Su Province China Tel 86 512 67625700 Fax 86 512 67617337 Email cnsales onyx healthcare com ...

Страница 6: ...Slim Medical Panel PC O N Y X 1 2 2 Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com ...

Страница 7: ...uld cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be...

Страница 8: ...UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 1950 for IT equipment and UL 60601 1 IEC 60601 series for systems shall comply with the standard IEC 60601 1 1 Safety requirements for medic...

Страница 9: ...hock not classified 2 Degree of protection against the ingress of water IPX1 3 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 4 Mode of operation Continuous 5 Type of protection against electric shock Class I equipment ...

Страница 10: ...ce complies with Part 15 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Страница 11: ...Slim Medical Panel PC O N Y X 1 2 2 UL Module Description Onyx 122 AC modules are developed to suitable for the Classification Mark requirement ...

Страница 12: ...l equipment with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Attention consult ACCOMPANYING DOCUMENTS Ground wire Protective Ground wire Medical equipment with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 ...

Страница 13: ...Workstation 有毒有害物質或元素 部件名稱 鉛 Pb 汞 Hg 鎘 Cd 六價鉻 Cr VI 多溴聯苯 PBB 多溴二苯醚 PBDE 印刷電路板 及其電子元件 外部信號 連接器及線材 外殼 中央處理器 與記憶體 硬碟 液晶模組 光碟機 觸控模組 電源 O 表示該有毒有害物質在該部件所有均質材料中的含量均在 SJ T 11363 2006 標準規定的限量要求以下 X 表示該有毒有害物質至少在該部件的某一均質材料中的含量超出 SJ T 11363 2006 標準規定的限量要求 備註 一 此產品所標示之環保使用期限 系指在一般正常使用狀況下 二 上述部件物質中央處理器 記憶體 硬碟 光碟機 觸控模組為選購品 ...

Страница 14: ...uick Tour of the ONYX 122 2 3 2 3 Removing the rear maintenance cover 2 4 2 4 2 5 Hard Disk Drive HDD Installation 2 4 Chapter 3 Award BIOS Setup 3 1 System Test and Initialization 3 2 3 2 Award BIOS Setup 3 3 Chapter 4 Driver Installation 4 1 Installation 4 3 Appendix A Programming the Watchdog timer A 1 Programming A 2 A 2 ITE8712 Watchdog timer initial Program A 5 Appendix B I O Information B 1...

Страница 15: ...anel PC O N Y X 1 2 2 B 2 Memory Address Map B 2 B 3 IRQ Mapping Chart B 3 B 4 DMA Channel Assignments B 5 Appendix C Miscellanea C 1 General Cleaning Tips C 2 C 2 Cleaning Tools C 3 C 3 Scrap Computer Recycling C 5 ...

Страница 16: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 1 General Information 1 1 General Information Chapter 1 ...

Страница 17: ... a powerful computer into a slim and attractive chassis The ONYX 122 has 200 nits TFT displays with Full HD 1366 x 768 resolution and integrate with high brightness LCD It supports 2 5 Hard Disk Drive storage function and one Mini PCI for WLAN expansion Moreover they feature flexible I O ports such as four USB2 0 one RS 232 and one optional isolated COM one Gigabit Ethernet one PS 2 keyboard mouse...

Страница 18: ...2 Feature 11 6 WXGA colorTFT LCD Easy To Use Compact Simple Design Fanless Zero Noise High Contrast Ratio Wide Viewing Angle For Medical Imaging Intel Core 2 Duo ULV Processor Resistive Touchscreen Optional 802 11a b g n Wireless Antenna Optional USB COM Isolation Optional ...

Страница 19: ...r 1 6GHz Drive Bay 2 5 Hard Disk Drive optional Expansion Mini PCI x 1 Button Brightness Sound Power SW I O RS 232 x 1 COM isolation x 2 optional USB 2 0 x 4 USB isolation x 1 optional 10 100 1000 Base TX x 1 PS 2 keyboard mouse x 1 Audio Line out LCD Specifications Model Name ONYX 122 Display Type 11 6 WXGA color TFT LCD Max Resolution 1366 x 768 Max Colors 262K colors Dot Size mm 0 1875 x 0 1875...

Страница 20: ...bjectionable under normal operation ONYX LCD panels are qualified for industry standard conditions in the following total 7 dead pixels on a screen or if there are 3 within 1 inch square area of each other on the display Mechanical Specifications Architecture Plastic casing and metal construction Front Bezel IP65 Plastic bezel with resistive touch screen Color Pearl White Mounting Holder Panel mou...

Страница 21: ...ating Temperature 0 C to 40 C 32 F 104 F Operating Humidity 30 75 Operating Atmospheric Pressure 850 1000hpa Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 5 to 95 40 C non condensing Storage Atmospheric Pressure 850 1000hpa Vibration 0 5G 5 500Hz Random operation Shock 15G peak acceleration 11 msec duration operation Drop 76cm 1 Corner 3 Edge 6 Surface EMI Safety CE FCC Class B UL 60...

Страница 22: ...ical Panel PC O N Y X 1 2 2 Chapter 1 General Information 1 7 TouchScreen Optional Type 4 wire Analog Resistive Interface USB Interface Resolution 2048 x 2048 Light Transmission 78 2 Life Time 10 million times ...

Страница 23: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 1 General Information 1 8 1 4 Dimension ...

Страница 24: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 2 Hardware Installation 2 1 Hardware Installation Chapter 2 ...

Страница 25: ... power is on because a sudden rush of power can damage sensitive electronic components Always ground yourself to remove any static charge before touching the board Modern electronic devices are very sensitive to static electric charges please remember to use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they ar...

Страница 26: ...he ONYX 122 upright on the desktop its front panel appears as shown in Picture 2 1 Picture 2 1 Front View of the Medical Station When you turn the Medical Station around and look at its rear cover the sunken I O section is at the bottom of the station as shown in Picture 2 2 The I O section includes various I O ports including DC in Serial ports VGA PS2 Ethernet USB Only assemble with the Mini PCI...

Страница 27: ... 2 4 Figure 2 2 Rear view of the Medical Station 2 3 Removing the rear maintenance cover Pull USB cover Unscrew the attachment screws used to hold the rear maintenance cover and remove rear cover 2 4 2 5 Hard Disk Drive HDD Installation 1 Unscrew the rear cover screws ...

Страница 28: ...C O N Y X 1 2 2 Chapter 2 Hardware Installation 2 5 2 Remove rear cover and unscrew the disk module screws 3 Assemble 2 5 HDD into disk module Take out LCD BRACKET Put into 2 5 HDD and screws Put 4 anti virbration cushion ...

Страница 29: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 2 Hardware Installation 2 6 4 Put 4 white screw nuts and put hard disk on it 5 Put 4 anti virbration screws and connect HDD cable to 2 5 HDD connector ...

Страница 30: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 3 Award BIOS Setup 3 1 Award Chapter 3 BIOS Setup ...

Страница 31: ... F1 key to continue the boot up sequence System configuration verification These routines check the current system configuration against the values stored in the CMOS memory If they do not match the program outputs an error message You will then need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS set...

Страница 32: ...his will allow you to enter Setup Standard CMOS Features Use this menu for basic system configuration Date time IDE etc Advanced BIOS Features Use this menu to set the advanced features available on your system Advanced Chipset Features Use this menu to change the values in the chipset registers and optimize your system performance Integrated Peripherals Use this menu to specify your settings for ...

Страница 33: ...operate Load Optimized Defaults Use this menu to load the BIOS default values that are factory settings for optimal performance system operations While AWARD has designated the custom BIOS to maximize performance the factory has the right to change these defaults to meet their needs Set Supervisor User Password Use this menu to set Supervisor User Passwords Save and Exit Setup Save CMOS value chan...

Страница 34: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 3 Award BIOS Setup 3 5 each setting in this chapter ...

Страница 35: ...Slim Medical Panel PC O N Y X 1 2 2 Chapter 4 Driver Installation 4 1 Driver Installation Chapter 4 ...

Страница 36: ...t the driver CD the driver CD title will auto start and show the installation guide If not please follow the sequence below to install the drivers Follow the sequence below to install the drivers Step 1 Install Intel INF Driver Step 2 Install Intel VGA Driver Step 3 Install Intel LAN Driver Step 4 Install Audio Driver Step 5 Install Touch Driver Please read instructions below for further detailed ...

Страница 37: ...tall the driver automatically Step 2 Install Intel VGA Driver 1 Click on the Step 2 VGA Driver folder and select the OS folder your system is 2 Double click on the Setup exe file located in the OS folder 3 Follow the instructions that the window shows 4 The system will help you install the driver automatically Step 3 Install Intel LAN Driver 1 Click on the Step 3 LAN Driver folder and select the O...

Страница 38: ...ile located in the OS folder 3 Follow the instructions that the window shows 4 The system will help you install the driver automatically Step 5 Install Touch Panel Driver 1 Click on the Touch driver folder and select the corresponding folder for your operating system and double click on Setup exe file 2 Follow the instructions that the window shows you 3 The system will help you install the driver...

Страница 39: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix A Miscellaneous A 1 Programming the Watchdog Timer Appendix A ...

Страница 40: ...n Configuring Sequence Description After the hardware reset or power on reset the ITE 8712 enters the normal mode with all logical devices disabled except KBC The initial state enable bit of this logical device KBC is determined by the state of pin 121 DTR1 at the falling edge of the system reset during power on reset There are three steps to complete the configuration setup 1 Enter the MB PnP Mod...

Страница 41: ...ided to select configuration ports 2Eh 2Fh of the next step 2 Modify the Data of the Registers All configuration registers can be accessed after entering the MB PnP Mode Before accessing a selected register the content of Index 07h must be changed to the LDN to which the register belongs except some Global registers 3 Exit the MB PnP Mode Set bit 1 of the configure control register Index 02h to 1 ...

Страница 42: ...hardware reset will automatically clear the bits and does not require the software to clear them WatchDog Timer Control Register Index 71h Default 00h WatchDog Timer Configuration Register Index 72h Default 0 WatchDog Timer Time out Value Register Index 73h Default 00h ...

Страница 43: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix A Miscellaneous A 5 ...

Страница 44: ...n CALL Enter_Configuration_mode CALL Check_Chip mov cl 7 call Set_Logic_Device time setting mov cl 10 10 Sec dec al Watch_Dog_Setting Timer setting mov al cl mov cl 73h call Superio_Set_Reg Clear by keyboard or mouse interrupt mov al 0f0h mov cl 71h call Superio_Set_Reg unit is second mov al 0C0H mov cl 72h call Superio_Set_Reg ...

Страница 45: ...tial_OK CALL Exit_Configuration_mode MOV AH 4Ch INT 21h Enter_Configuration_Mode PROC NEAR MOV SI WORD PTR CS Offset Cfg_Port MOV DX 02Eh MOV CX 04h Init_1 MOV AL BYTE PTR CS SI OUT DX AL INC SI LOOP Init_1 RET Enter_Configuration_Mode ENDP Exit_Configuration_Mode PROC NEAR MOV AX 0202h CALL Write_Configuration_Data ...

Страница 46: ... ENDP Check_Chip PROC NEAR MOV AL 20h CALL Read_Configuration_Data CMP AL 87h JNE Not_Initial MOV AL 21h CALL Read_Configuration_Data CMP AL 12h JNE Not_Initial Need_Initial STC RET Not_Initial CLC RET Check_Chip ENDP Read_Configuration_Data PROC NEAR MOV DX WORD PTR CS Cfg_Port 04h OUT DX AL ...

Страница 47: ...ta ENDP Write_Configuration_Data PROC NEAR MOV DX WORD PTR CS Cfg_Port 04h OUT DX AL XCHG AL AH MOV DX WORD PTR CS Cfg_Port 06h OUT DX AL RET Write_Configuration_Data ENDP Superio_Set_Reg proc near push ax MOV DX WORD PTR CS Cfg_Port 04h mov al cl out dx al pop ax inc dx out dx al ret Superio_Set_Reg endp Set_Logic_Device proc near ...

Страница 48: ...ax push cx xchg al cl mov cl 07h call Superio_Set_Reg pop cx pop ax ret Set_Logic_Device endp Select 02Eh Index Port 02Fh Data Port Cfg_Port DB 087h 001h 055h 055h DW 02Eh 02Fh END Main Note Interrupt level mapping 0Fh Dh not valid 0Ch IRQ12 03h IRQ3 02h not valid 01h IRQ1 00h no interrupt selected ...

Страница 49: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 1 I O Information Appendix B ...

Страница 50: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 2 B 1 I O Address Map B 2 Memory Address Map ...

Страница 51: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 3 B 3 IRQ Mapping Chart ...

Страница 52: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 4 ...

Страница 53: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 5 B 4 DMA Channel Assignments ...

Страница 54: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix B I O Information B 6 ...

Страница 55: ...Slim Medical Panel PC O N Y X 1 2 2 Appendix C Miscellanea C 1 Miscellanea Appendix C ...

Страница 56: ... you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals wh...

Страница 57: ...g that component if this is the case it will be mentioned in the cleaning tips Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth Water or rubbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the comp...

Страница 58: ...keyboard mouse and other locations Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components Please follow the steps below 1 Close all application programs 2 Close operating software 3 Turn off power switch 4 Remove all device 5 Pull out power cable ...

Страница 59: ...e strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national requirements to dispose unit ...

Отзывы: