Heckert Solar NeMo 4.1 80 M Скачать руководство пользователя страница 1

Installation

 and operating manual

 

PV-Modul

e

 

NeMo 4.1

 80 M

www.heckert-solar.com

 

S

tatus

 0

8

/2022 

Standard 11 years 

product warranty

Produced with 

green energy

Made in Germany

Содержание NeMo 4.1 80 M

Страница 1: ...Installation and operating manual PV Module NeMo 4 1 80 M www heckert solar com Status 08 2022 Standard 11 years product warranty Produced with green energy Made in Germany...

Страница 2: ...ime Heckert Solar reserves the right to amend the present document at any time without prior notice Please use the most current copy which can be found on our homepage at https www heckertsolar com se...

Страница 3: ...e output of solar modules decreases considerably as the modules heat up Rear ventilation avoids yield impairing heat accumulation The so called chimney effect draught behind the modules should not be...

Страница 4: ...care when unpacking transporting and storing the modules We recommend keeping the modules in their packaging until ready for installation Always set the pallets on a reinforced level ground and do not...

Страница 5: ...ard ground Do not set the modules down on their corners Do not place the modules on top of each other unprotected Do not place any objects on the modules Never stand on the modules Do not allow the mo...

Страница 6: ...not use any lenses or mirrors to concentrate light risk of overheating Avoid damage to the module from using carbide or diamonds Protect solar modules from overvoltage e g voltage peaks from battery...

Страница 7: ...mounting rails Ensure that the connector sockets and cables when necessary are not damaged or exert pressure on the cells The total snow load on the ground sk in kN m results from the respective snow...

Страница 8: ...re 2400 Pa Pressure 8100 Pa Pressure 5400 Pa Suction 2400 Pa Suction 1600 Pa Suction 2400 Pa Suction 1600 Pa Clamp short side A 150 B 150 4 fixing points in the corners internal clearance A 10 B 200 T...

Страница 9: ...r the crimping of connectors Defective crimped connections may cause significant damage to the modules and could even cause the plant to burn down The modules are connected to the strings in series Th...

Страница 10: ...e 5 Connected MC4 modules The string cables are connected to the MC4 connectors on the first or last module in the string The connectors comply with IEC 62852 Please be sure to observe the requirement...

Страница 11: ...rings and should be laid together When connecting the strings to the inverter ensure that its polarity is correct The and cables must not be interchanged Using a multimeter voltmeter the polarity and...

Страница 12: ...arried out using a spring washer or toothed washer to ensure that the anodized layer is penetrated Figure 8 Equipotential bonding symbol and execution Functional earthing Functional earthing is requir...

Страница 13: ...aimer These installation and operating instructions apply to general installations All information is supplied without guarantee Heckert Solar GmbH shall assume no liability for the usability and func...

Страница 14: ...32 6029 156 Conductor cross section 4 6 IO mm2 Type PV AZM 4 I0 Order no 32 6027 410 ill 2 Crimping pliers PV CZM incl locator and built in crimping insert Crimping range 1 5 2 5 4 mm2 14 12 AWG Type...

Страница 15: ...n ended spanner ill 8 SW 12 Torque wrench Preparing the line Connecting lines with a stranded wire construction of classes 5 and 6 can be connected Warning Do not use bare or already oxidised conducto...

Страница 16: ...emove the insulation of the cable over a length of 6 0 to 7 5 mm Warning Do not cut any individual wires when stripping Note 1 In order to use the stripping pliers PV AZM and replace the sets of blade...

Страница 17: ...e crimp die ill 13 Insert the stripped cable until the insulation touches the crimp insert Close the crimping pliers completely ill 14 Visually check the crimping Note please refer to the operating in...

Страница 18: ...nted the white marking on the test pin must still be visible ill 17 Hand tighten the cable gland with the PV MS tools or tighten the cable gland with the PV WZ AD GWD and PV SSE AD4 tools In both case...

Страница 19: ...cable coupling without securing sleeve PV SSH4 Plugging ill 20 Plug the cable coupling together until it engages Check that it engages correctly by pulling on the cable coupling Unplugging The cable...

Отзывы: