LP GAS CYLINDER
QCC
®
-1 QUICK CLOSING COUPLING
The QCC
®
-1 system incorporates new safety features
required by the American National Standards Institute
(ANSI) and the Canadian Standards Steering Committee.
* Gas will not
fl
ow until a positive connection
has been made.
* A thermal element will shut off the
fl
ow of gas
between 240° and 300° F.
* When activated, a Flow Limiting Device will
limit
the
fl
ow of gas to 10 cubic feet per hour.
The LP Gas Cylinder is not included with the Gas Grill. Be
sure to purchase one with the QCC
®
valve. This valve is
recognized by the external threads on the inlet port of the
valve. QCC
®
equipped cylinders are available from your
Gas Grill Dealer.
Any attempt to connect the regulator, by use of adapters
or any other means, to any other valve could result in
damage,
fi
re or injury and may negate the important safety
features designed into the QCC
®
-1 system.
SPECIFICATION:
1. All LP gas cylinders used with this appliance must
be constructed and marked in accordance with
the
Speci
fi
cations for LP Gas Cylinders
of the U.S.
Department of Transportation (D.O.T.) or the
National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission
, as applicable; and
2. The LP gas cylinder used for this appliance must not
have a capacity larger than 20 lb. (9 kg).
Approximately 18” (46cm) high
12” (31cm) diameter
3. All LP gas cylinders used with this appliance should
be inspected at every
fi
lling and re quali
fi
ed by a
licensed service outlet at the expiry date (10 years), in
accordance with the DOT (USA) and CTC (Canada)
codes for LP Gas Cylinders.
4. All LP gas cylinders used with this appliance must be
provided with a shutoff valve terminating in a cylinder
valve outlet No. 510, speci
fi
ed in the Standard for
Compressed Gas Cylinder Valve Outlet and Inlet
Connection (USA) ANSI/CSA-V-1-1977 (Canada) CSA
B96.
The cylinder supply system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect
the cylinder valve. The cylinder must be installed as per
assembly instructions. Never
fi
ll the cylinder beyond
80% full. A
fi
re causing death or serious injury may
occur. The cylinder valve must include a safety relief
device having direct communication with the vapor
space of the cylinder.
HANDLING:
1. Government regulations prohibit shipping full LP gas
cylinders. You must take your new cylinder to a LP gas
dealer for
fi
lling.
2. A
fi
lled LP gas cylinder is under very high pressure.
Always handle carefully and transport in the upright
position. Protect the valve from accidental damage.
3. Do not tip the LP gas cylinder while connecting it to the
regulator. Fasten the cylinder securely during transport,
use and storage.
4. If the cylinder is tipped after it is connected to the
regulator, shut off the gas, disconnect the regulator and
have it checked before using again.
STORAGE:
1. Store the LP gas cylinder outdoors in a well ventilated
place.
2. Do not store the LP gas cylinder in direct sunlight, near
a source of heat or combustion.
3. If you intend to store the grill indoors, disconnect and
remove the LP gas cylinder
fi
rst. Disconnected cylinders
must have a dust cap installed and must not be stored
in a building, garage or any other enclosed area.
4. Keep out of the reach of children.
5. When the LP gas cylinder is connected to the gas grill,
the gas grill and LP gas cylinder must be stored outside
in a well ventilated place.
OPERATION:
1. Never connect your gas grill to an LP gas cylinder
without the regulator provided, and
NEVER TO AN
UNREGULATED LP GAS SUPPLY.
The gas regulator
supplied with the appliance must be used.
2.
Always
leak test the LP gas cylinder to regulator
connection when connecting the LP gas cylinder to the
appliance. See “Leak Testing”.
3.
DO NOT
operate appliance if the smell of LP gas is
present. Extinguish all
fl
ame and determine source of
LP gas before proceeding.
DO NOT
ignite the appliance
until the LP gas leak has been found and sealed.
4.
Always
shut off LP gas cylinder valve when the
appliance is not in use.
4