Onvif IPPTZ-EL2MPL30X-AT Скачать руководство пользователя страница 24

 

18

AUTO SCAN NO   

001

SET LEFT LIMIT 

SET RIGHT LIMIT    

SCAN SPEED         

160 

CALL 

STOP 

BACK                       EXIT 

2.4.4.2

 Pan 

 
 
 
 

Move the cursor to PAN button and then click confirm button to go to setup interface.  

z

  PAN SPEED: Set dome rotation speed. Please use the left/right button on the keyboard or in the speed 

dome terminal menu to set.    

z

  CALL: Move the cursor to call item and then click confirm button. The dome begins 360 degrees 

continuous rotation. 

z

  STOP: Highlight stop item and then click confirm button. The dome stops rotation. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

 
2.4.4.3

 Scan 

 

 
 
 
 
 

Move the cursor to SCAN button and then click confirm button. 

z

  AUTO SCAN NO

Here is to set auto scan number. Please use the left/right button on the keyboard or 

in the speed dome terminal menu to set.    

z

  SET LEFT LIMIT

Here is to set camera left address. Click confirm button to save current setup. 

z

 SET 

RIGHT 

LIMIT

Here is to set camera right address. Click confirm button to save current setup. 

z

  SCAN SPEED: Please use the left/right button on the keyboard or in the speed dome terminal menu to 

set.     

z

  CALL: Please input auto scan number first, and then please move the cursor to CALL and click confirm 

button to activate auto scan function.  

z

  STOP: Here is to terminate auto scan function. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

 

2.4.4.4

  Tour 

 
 
 

 
 
 
 

Move the cursor to highlight TOUR item and then click confirm button to go to set interface.  

z

 TOUR 

NO 

Here is to ser tour number. Please use the left/right button on the keyboard or in the speed 

dome terminal menu to set.    

TOUR   NO

          

001

TOUR SETTING 

DELETE TOUR 

RUN 

STOP 

BACK                           EXIT 

PAN SPEED    

160

CALL 

STOP 

BACK               EXIT 

Содержание IPPTZ-EL2MPL30X-AT

Страница 1: ...IPPTZ EL2MPL30X AT User s Manual Version 1 0 0...

Страница 2: ...2 9 Defog 1 1 2 10 3D noise reduction 2 1 2 11 Action on Alarm 2 1 2 12 Auto Flip 2 1 2 13 Self diagnosis 2 1 2 14 Day Night Mode B W Color Mode 2 1 2 15 Auto Focus 2 1 2 16 Backlight Compensation 2 1...

Страница 3: ...enomenon Operation 24 2 5 1 Restore to Factory Default Setup 24 2 5 2 PTZ Movement is not smooth 24 3 CABLE CONNECTION 25 3 1 Combination Cable Connection 25 3 2 System Layout 25 3 2 1 System Connecti...

Страница 4: ...eference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Befor...

Страница 5: ...device This series product complies with the IP66 standard specified in the Degrees of Protection Provided by Enclosure z Please make sure the CCD CMOS component is out of the radiation of the laser...

Страница 6: ...use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if somethi...

Страница 7: ...quick installation HD network speed dome continually decreases or increases pan and tilt speeds in proportion to depth of zoom When zooms speed is increasing the camera moving speed becomes slow When...

Страница 8: ...This function needs the speed dome driver camera supported 1 2 15 Auto Focus Support camera auto focus function 1 2 16 Backlight Compensation Balance the brightest and darkest sections of a scene to...

Страница 9: ...a IP address and PC IP address shall be in the same network segment if there is no router Network camera default IP address is 192 168 1 108 If there is a router please set the corresponding gateway a...

Страница 10: ...ick the Login button to go to the login interface See Figure 1 4 In Figure 1 4 you can view device IP address user name password and port Please modify the corresponding information to login Please no...

Страница 11: ...assword admin 1 4 1 Network Connection Please follow the steps listed below for network connection z Make sure the speed dome has connected to the network properly z Speed dome IP address and PC IP ad...

Страница 12: ...tem is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the I...

Страница 13: ...ection type Note For security reasons please modify your password after you first login Figure 1 3 After you logged in you can see the main window See Figure 1 4 Figure 1 4 Please refer to the Web Ope...

Страница 14: ...z Please make sure all the cable connections are right 2 2 Self diagnosis System Information PRESET AZIMUTH DISP TIME DISP POSITION ZOOM DISP INSIDE TEMP TITILE DISPLAY BACK EXIT DISPLAY SETTING SYSTE...

Страница 15: ...eyboard matrix or speed dome control terminal z SYSTEM SETTING Display speed dome system information address information Here you can set north direction language factory default setup reboot and so o...

Страница 16: ...ou to select Please use the left right button on the keyboard or in the speed dome terminal menu to set z FACTORY DEFAULT Restore dome factory default setup Please move the cursor to the option and th...

Страница 17: ...information Please use the left right button to set z BACK Go back to the previous menu z EXIT Log out system menu 2 4 3 Camera Setting Before the operation please make sure your camera supports the...

Страница 18: ...door outdoor and outdoor auto sodium lamp auto and sodium lamp and etc Please use the left right button on the keyboard or in the speed dome terminal menu to set z R GAIN Before you set R GAIN option...

Страница 19: ...right button to set o SLOW SHUTTER LOW LIMIT Please click the left right button to set o NOISE REDUCTION There may noise when the camera is monitoring the low illumination environments You can use the...

Страница 20: ...Night Setting Move the cursor to DAY NIGHT SETTING and then click confirm button you can go to the submenu z DAY NIGHT It is to set camera day night switch mode It includes auto schedule color B W Pl...

Страница 21: ...s to set picture saturation Please use the left right button on the keyboard or in the speed dome terminal menu to set z CHROMA SUPPRESS It is to set picture color control Please use the left right bu...

Страница 22: ...It is to set air light intensity value It is valid when the air light intensity mode is manual Please use the left right button on the keyboard or in the speed dome terminal menu to set z BACK Go bac...

Страница 23: ...to identify the camera System will automatically name a title for the camera z SETTING Please input preset number first and then select the monitor zone Please move the cursor to setting and click con...

Страница 24: ...the keyboard or in the speed dome terminal menu to set z SET LEFT LIMIT Here is to set camera left address Click confirm button to save current setup z SET RIGHT LIMIT Here is to set camera right add...

Страница 25: ...e tour Input tour number in tour NO and highlight CALL click confirm button to activate touring z STOP Here is to terminate touring z BACK Go back to previous menu z EXIT Log out system menu 2 4 4 5 P...

Страница 26: ...ton on the keyboard or in the speed dome terminal menu to set z IDLE ACTION There are several functions you can select NONE PRESET SCAN TOURING PATTERN Please use the left right button on the keyboard...

Страница 27: ...to the SAVE button to save current setup z END TIME Here you can set the task end time Move the cursor to current item and then click confirm button to set the time Please use the up down button to s...

Страница 28: ...z PTZ AUTO STOP The speed dome will stop all the PTZ operations when there is no command for the specified time It includes various setups Please use the left right button to set z BACK Go back to the...

Страница 29: ...confirm button you can go to the fourth menu POWER UP It is to set the PTZ operation when the speed dome boots up The option includes NONE AUTO SCAN PRESET PATTERN TOUR and etc Please use the left ri...

Страница 30: ...ove cursor to FACTORY DEFAULT and click confirm button Dome will reboot and all the setups restore to factory default setup 2 5 2 PTZ Movement is not smooth From menu to SYSTEM INFORMATION move cursor...

Страница 31: ...port AUDIO IN Audio input port GND Ground port VIDEO OUT Video output port LAN Network port Connect to network cable z Seven alarm input channels It is to receive relay signal from the external alarm...

Страница 32: ...Please refer to Figure 3 1 for system connection information Figure 3 1 3 2 2 Alarm Connection Please refer to Figure 3 2 for alarm connection information Figure 3 2 Network Output AC220V Input Transf...

Страница 33: ...me to power Red LED light on the power board is on z Power supplying is low z Something wrong with power board z Use multimeter to check dome load z Please contact retailer to replace power board Powe...

Страница 34: ...e point to the earth Open floor cable layout is forbidden z In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install addit...

Страница 35: ...ndicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environme...

Страница 36: ...ware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please re...

Отзывы: