15
Measuring Method
FP-4135 On-Board Volumetric Flow Detector
5.
Measuring Method
This section describes the measurement procedure combining the Ono Sokki DF-2200 On-Board Flow Meter or FM
Series Digital Flowmeter to the FP-4135 On-Board Volumetric Flow Detector.
5.1 Basic measurement procedure
Start
End
Configuring FACTOR
Assembling measurement system
Checking piping
Pouring liquid
Air bleeding
Start measurement
•
Assembling the measurement system means the
procedures up to connecting the FP-4135 On-Board
Volumetric Flow Detector to the DF-2200 On-Board Flow
Meter or the FM Series Digital Flowmeter using the signal
cables.
•
Input (configure) the FACTOR value and the Flow Pulse
to Ono Sokki DF-2200 On-Board Flow Meter or the FM
Series Digital Flowmeter.
•
Before pouring liquid into the FP-4135 On-Board
Volumetric Flow Detector, check again that the piping is
correct.
•
Pour liquid into the FP-4135 On-Board Volumetric Flow
Detector.
•
After checking the piping for any leaks before
measurement, bleed the air completely from the piping
and the FP-4135 On-Board Volumetric Flow Detector.
If the air is not vented completely, it might cause
measurement errors and/or fluctuation of the
instantaneous flow rate.
•
After every preparation and procedure is complete, start
the measurement.
1)
2)
3)
4)
5)
6)
Содержание FP-4135
Страница 1: ...ON BOARD VOLUMETRIC FLOW DETECTOR FP 4135 Instruction Manual ONO SOKKI CO LTD...
Страница 14: ...12 Installation Method Signal processing part 72 60 5 5 5 5...
Страница 30: ...28 Maintenance and Storage...
Страница 31: ......