8
System Configuration
2.
System Configuration
Configure the system according to your intended use and purpose, referring to the table below.
- Display Unit -
●FM-1500 Digital Flowmeter
●FM-2500A Digital Flowmeter
●DF-2200 On-Board Flow Meter
FP-4135 On-Board Volumetric Flow Detector -
(flow detecting part)
Temperature detector (straight out from cable 2 m)
Flow Detector (straight out from cable 2 m)
Temperature signal cable
Flow Signal Cable
Connector
Model name of temperature signal cable Full length
FP-0025
5 m
FP-0026
10 m
FP-0027
20 m
Model name of flow signal cable
Full length
FP-0015
5 m
FP-0016
10 m
FP-0017
20 m
POWER
SETUP
L / g
DENS/CD
INSTANT
TOTAL/LAP
RESET
STOP
HOLD
START
ESC
NEXT
ENTER
>
>
䠚
䠚
FZ-ONLY
FM-1500
Flow Meter
POWER
1
2
DISP COND
3
MENU
ESC
ENTER
RESET
START
HOLD
STOP
MEAS
DISP
ALL
DISP
LOCAL
FM-2500A
Flow Meter
*1: FP-4135 On-Board Volumetric Flow Detector does not come with a pressure sensor. If you need to measure pressure, please contact
the nearest Ono Sokki sales office or the distributor where you purchased the product.
*2: It is an optional function.
FP-4135 On-Board Volumetric Flow Detector-
(signal processing part)
Model name
FM-2500A + DF-0400A
Measuring item Instantaneous flow rate/
Accumulated flow rate/
Accumulated time/
Temperature/Pressure*
1
Output signal
Analogue pulse/RS-232C/GP-IB*
2
Model name
DF-2200
Measuring item Instantaneous flow rate/
Accumulated flow rate/
Accumulated time/
Temperature/Pressure*
1
Output signal
Analogue pulse/CAN/RS-232C*
2
Model name
FM-1500 + DF-0400A
Measuring item Instantaneous flow rate/
Accumulated flow rate/
Accumulated time/
Temperature/Pressure*
1
Output signal
Analogue pulse/RS-232C/GP-IB*
2
•
For some measurement targets, you might need detectors other than the FP-4135 On-Board Volumetric Flow Detector.
For details, contact the nearest Ono Sokki sales office or the distributor where you purchased the product.
•
The FP-4135 On-Board Volumetric Flow Detector is separated into a flow detecting part and a signal processing part.
•
The FM Series Digital Flowmeter requires the detecting module DF-0400A.
•
FP-4135 On-Board Volumetric Flow Detector does not come with a pressure sensor. If you need to measure pressure,
please contact the nearest Ono Sokki sales office or the distributor where you purchased the product.
!