DIO option
The Helix platform supports an optional Isolated Digital I/O add-in card through a 10-pin terminal
block (Mating connector: Phoenix Contact pn: #1840447 or similar). This option allows for integration
of the Helix platform with existing PLC integrations or other digital logic applications. The Digital IO
may be managed through the sideband Programmable Services Engine, via the Host Embedded
Controller Interface (HECI). Windows drivers are available for this interface, and a command line tool
is available for download from our support website. For a complete explanation of features, operating
voltages, and safety information, please refer to the DIO expansion manual on the OnLogic support
site.
Pin 10
Pin 9
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
GND
In 4
In 3
In 2
In 1
Out 4
Out 3
Out 2
Out 1
Power
Helix DIO Support Site
https://www.onlogic.com/support/documentation/hx300-technical-resources
Dual LAN option
The HX330 supports up to two additional LAN ports on the front Modbay slot of the system. Both
ports are Intel I210 network controllers.