Onicon F-5000 Скачать руководство пользователя страница 7

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

F-5000 Software Manual 09/16 - 2032 / 107050 

Page  7

i

i

To install the F-5000 View program, run the "F-5000View_V#.##-setup.exe" file that 
is located in the sub-folder of the downloaded file.  After clicking "Next" the screen will 
show:

Select the folder in which you wish to install F-5000 View, then click "Install".

When the program is done installing, you may exit, then restart your computer.

Note: The F-5000 View software will automatically detect the model type (F-5500 or 
F-5400). 

Note: Some features that are available on the F-5500 will not be available for the 
F-5400 and will not appear as options to configure using this software program.

Installation

F-5000 View

INST

ALL

A

TION

Installation

Содержание F-5000

Страница 1: ... Road South Largo FL 33773 USA Tel 1 727 447 6140 Fax 1 727 442 5699 www onicon com sales onicon com F 5000 View Software Installation and Operation Guide 10 16 2032 1 107050 Rev B ONICON Flow and Energy Measurement ...

Страница 2: ... herein is accurate however be advised that the information contained herein is NOT a guarantee for satisfactory results Specifically this information is neither a warranty nor guarantee expressed or implied regarding performance merchantability fitness or any other matter with respect to the products nor recommendation for the use of the product process information in conflict with any patent Ple...

Страница 3: ... Contents F 5000View TABLE OF CONTENTS 1 Introduction Page 5 2 Installation Page 6 3 Operation Page 9 a Main Screen Page 9 b Charts Settings Page 11 c Configure Page 13 d Data Logger Page 19 e Simulation Mode Page 21 f Zero CAL CHECK Test Page 23 g Zero CAL CHECK Certificate Page 23 4 Glossary of Terms and Abbreviations Page 26 5 Index Page 27 F 5000View ...

Страница 4: ...ts in the product which were not predictable or for any indirect damages Safety Precautions The following general safety precautions must be observed during all phases of installation operation service and repair of this product Failure to comply with these precautions or with specific WARNINGS given elsewhere in this manual violates safety standards of design manufacture and intended use of the p...

Страница 5: ...liability The F 5000 View software allows users to easily display data and configure the F 5000 to their specific application parameters Then log flow temperature data to an Excel file Note For the Model F 5500 flow meter only the software can also access the Calibration Validation diagnostic function using the Zero CAL CHECK test This Manual contains the installation and operation instructions fo...

Страница 6: ...meter to a PC or laptop using the mini USB port type A mini cable If the PC is connected to the Internet and running Windows 7 8 the PC will try to automatically load the VCP driver If the driver does not load automatically download the VCP driver at www ftdichip com Drivers VCP htm Note The latest version of the F 5000 View software is available for download at www onicon com 5500 or www onicon c...

Страница 7: ...clicking Next the screen will show Select the folder in which you wish to install F 5000 View then click Install When the program is done installing you may exit then restart your computer Note The F 5000 View software will automatically detect the model type F 5500 or F 5400 Note Some features that are available on the F 5500 will not be available for the F 5400 and will not appear as options to ...

Страница 8: ...ign a virtual COM port The COM port number that has been assigned will appear automatically in the drop down box If the correct COM Port does not appear go to Control Panel Device Manager and click on Ports COM LPT The COM port number should be displayed under the USB symbol If prompted enter the assigned COM port in F 5000 View by using the drop down menu and press OK Note The flow meter must be ...

Страница 9: ...on the screen is refreshed at user selected update rate See p 11 for more information on setting up Charts Charts Button This calls up two charts that can be configured for either temperature or flow Each chart can be individually enlarged and rescaled from the original default settings For more information on how to change the charts settings refer to Operation Chart Settings on page 11 Note It c...

Страница 10: ...y The easiest way to perform this check is to enter a specific temperature flow rate The corresponding analog outputs can be verified using a DMM and using a watch for the pulse Refer to Page 21 for more information on how to use the Simulation function Zero CAL CHECK available only on Model F 5500 The Zero CAL CHECK calibration validation test can be performed while the unit is still in the pipe ...

Страница 11: ...n click on Charts Two charts one for flow and the other for temperature will appear side by side Fig 3 2 Chart Settings Window Charts 1 and 2 Each chart can be selected for flow temperature or total flow and scaled in one of three ways a plus minus percent scale inputting min max values manually or real time automatic scaling Operation Chart Settings Charts Settings F 5000View OPERATION ...

Страница 12: ...s the number of points plotted on the graph Older data is automatically omitted Update Rate The update rate controls the data refresh rate Percent Scale This sets the scale to a plus minus specified percentage from the initial measured value Typically the minimum maximum is scaled at plus minus 10 of that initial value Manual Chart Setting The Manual mode allows a user to input min max values for ...

Страница 13: ...e requested password for either Level I 1234 or Level II 9111 access Fig 3 3 Password Window Note Most users will only need access to the Level I screen to do basic setting of units alarms and output scaling F 5000 View software is an intuitive program that automatically recognizes meter model and configuration that determines which of the following screens will appear Operation Configure Configur...

Страница 14: ...he flow meter has been calibrated to measure 5 The pulse settings will only show on a flow meter that has been ordered with the Pulse Option 6 The Save Restore Parameter options are not available using a Level 1 password 7 The serial communication settings can be accessed by clicking on the Serial COM Settings button The serial communication settings will only show on a flow meter that has been or...

Страница 15: ...F 5500 only With the top four drop down boxes the user can choose the data to display By selecting Alternate the screen automatically switches between the data screens Alarm Limits Users can set both high and low alarms for both flow and temperature When a limit is reached an alarm message is displayed and the digital output is activated The digital output can be used to control an external buzzer...

Страница 16: ...lection configures the F 5000 digital output for either pulses counts or an alarm output Pulse Output Scaling If the pulse counts output is selected the pulse scaling can be programmed three different ways using the menu Pulse Output Configuration Units per Pulse example 10SCF Pulse Maximum flow and maximum frequency Pulses per Unit Note If RS485 option has been ordered on a F 5500 meter the Pulse...

Страница 17: ...ftware Manual 10 16 2032 107050 Page 17 i Fig 3 6 Confirmation of Saved Configuration Window Recall Configuration to File This allows the operator to recall an existing configuration file Note This feature is only accessed with a Level II password Operation Configure F 5000View OPERATION Recall Configuration ...

Страница 18: ... only available on a F 5500 meter configured for RS485 Modbus RTU and BACnet MS TP Serial COM Settings Use this function to set the serial communication settings for any of the optional F 5000 bus communication boards Fig 3 7 Select Serial Communication Window MODBUS Fig 3 8 Select Serial Communication Window BACnet F 5000View OPERATION Operation Configure Serial COM Settings ...

Страница 19: ...d South Largo FL 33773 USA Tel 1 727 447 6140 Fax 1 727 442 5699 sales onicon com F 5000 Software Manual 10 16 2032 107050 Page 19 Fig 3 9 Select Serial Communication Window HART Operation Configure F 5000View OPERATION ...

Страница 20: ...n Fig 3 11 Data Logger Window Logging Turned On When Start Data Logging is pressed the data is recorded in the specified Excel file and also displayed in the Data Logged window Pressing Stop Data Logging ends data acquisition Data Logger The Data Logger screen can be accessed from the main screen Clicking the Data Logger function will prompt the user for a password Enter a Level I or Level II pass...

Страница 21: ... shown Fig 3 12 Simulation Mode Window The simulation mode simulates flow rate temperature and or Current Sense Voltage CSV Click on the required data and enter a value Simulation mode allows users to verify the analog output digital output and totalizer at simulated flow rates and temperature Fig 3 13 Entering a Simulation Value Enter the value click OK select the corresponding checkbox and press...

Страница 22: ... sales onicon com F 5000 Software Manual 10 16 2032 107050 Page 22 Fig 3 14 Simulation Running In Simulation mode all F 5000 outputs and the Totalizer respond as if in normal measurement mode Click Halt Simulation to end F 5000View OPERATION Operation Simulation Mode Simulation Mode ...

Страница 23: ...he Zero CAL_CHECK button to access the Zero CAL CHECK Menu Window Fig 3 15 Zero CAL CHECK Menu Window On the Zero CAL CHECK Menu there are fields to enter information about the person performing the test meter tag information and any other important information may be entered into the comments area The user can also specify a particular folder name and location to save this data The data will be s...

Страница 24: ...indow During the test the Zero CAL CHECK button will display the current calculated value and a countdown timer of seconds left on the test Fig 3 17 Running a Zero CAL CHECK Test A Pass Fail message for the Zero CAL CHECK test will be displayed at the test conclusion Fig 3 18 Zero CAL CHECK Results Window F 5000View OPERATION Operation Zero CAL CHECK Zero CAL CHECK Zero CAL CHECK Results ...

Страница 25: ...the Zero CAL CHECK data A pass result confirms the meter is measuring accurately CALIBRATION VALIDATION Zero CAL CHECK CERTIFICATE Zero CAL CHECK Certificate The Zero CAL CHECK Certificate function displays the latest certification When performing a Zero CAL CHECK test all the data is logged into a log file with all pertinent data including the serial number A laptop or PC can be used to perform t...

Страница 26: ...l 10 16 2032 107050 Page 26 Aa Definitions Glossary of Terms and Definitions F 5000View DEFINITIONS COM Communication CSV Current Sense Voltage DMM Digital Multimeter ID Inner Diameter mA Milliamps PC Personal Computer RTD Resistance Temperature Detector STP Standard Temperature and Pressure TSI Temperature Sense Current ...

Страница 27: ...put Pulse Output enabled models only p 15 Filter value p 15 Flow cutoff p 15 Frequency Output Pulse Output enabled models only p 15 Parity RS485 enabled models only p 18 Password p 13 Pipe Area p 15 Reset Total p 13 Reset CRC p 13 Serial Communication RS485 enabled models only p 18 Unit settings p 15 Dampening factor p 15 Filter value p 15 Frequency Output Pulse Output enabled models only p 15 Glo...

Страница 28: ...i Caution Wiring Definition of Terms Troubleshooting Tips Information Aa ...

Отзывы: