background image

19

CONTROL SOLUTION TESTING

Press 

 so that the control solution test symbol 

CtL

 appears in the upper right corner of the 

display. You must mark the test before you apply control solution. Once you have completed 
the test, you cannot change the marking. The meter is now ready to perform a control solution 
test. If you decide not to do a control solution test, press 

 again to remove 

CtL

 from the 

display.

 Prepare and apply control solution

Shake the control solution vial before each test. Remove the cap and squeeze the vial to 
discard the first drop. Then wipe the tip with a clean tissue or cloth. Hold the vial upside 
down and gently squeeze a hanging drop. Touch and hold the hanging drop of control 
solution to the narrow channel in the top edge of the test strip. Make sure the confirmation 
window fills completely. Control solution should not be applied to the flat face of the test 
strip.

 Read your result

When the confirmation window is full, the meter will count down from 5 to 1. Your result will then 
appear on the display, along with 

CtL

 and the unit of measure.

 Check if the result is in range

Compare the result displayed on the meter to the control solution range printed 

on the test strip vial

. Each vial of 

test strips may have a different control solution range. If the results you get are not within this range, the meter and 
test strips may not be working properly. Repeat the control solution test.

Out-of-range results may be due to:
  •  not following the instructions detailed in steps 1–7,
  •  expired or contaminated control solution,
  •  expired or damaged test strip,
  •  use of a test strip or control solution past its discard date, or
  •  a problem with the meter.

 CAUTION:

 The control solution range printed on the test strip vial is for OneTouch® Ultra® Control Solution only. It is not a 

recommended range for your blood glucose level. 

 CAUTION: 

If you continue to get control solution results that fall outside the range printed on the test strip vial, 

Do Not

 use the 

meter, the test strips, or the control solution. Call the OneTouch® Customer Care Line at 1 800 663-5521.

Confirmation 

Window

5.5–7.4 mmol/L

(Example)

Top 

Edge

Narrow Channel

Apply drop here

Содержание ONETOUCH ULTRAMINI - MANUAL 2

Страница 1: ...USER GUIDE Blood Glucose Monitoring System AW 06629202A Rev date 04 2010...

Страница 2: ...a use license under these patents Such a license is granted only when the device is used with OneTouch Ultra Test Strips No test strip supplier other than LifeScan is authorized to grant such a licen...

Страница 3: ...for the quantitative measurement of glucose sugar in fresh capillary whole blood The OneTouch UltraMini System is intended for self testing outside the body invitro diagnostic use by people with diab...

Страница 4: ...h Customer Care Line 1 800 663 5521 Available separately e OneTouch Ultra Test Strips f OneTouch Ultra Control Solution g Clear Cap for AST testing Ask for control solution where you buy your test str...

Страница 5: ...play mmol L is the pre set unit of measure Up and down buttons Turns the meter on or off Select or change information Test port Insert test strip here to turn meter on for testing TEST STRIP Edge to a...

Страница 6: ...lay should appear briefly on the start up test screen to tell you that the meter is working properly To check that all display segments are working as soon as the start up test screen appears press an...

Страница 7: ...to be updated simply wait five seconds The meter display will automatically advance to the next setting Set the hour With the hour flashing on the display press and release or to go forward or backwar...

Страница 8: ...t flashing Set the month Press or to change the month When you have the correct month on the display wait five seconds to move to the next setting The day will now start flashing Set the day Press or...

Страница 9: ...the vial Hold the meter as shown and insert the test strip into the test port Make sure the three contact bars are facing you Push the test strip in as far as it will go Do Not bend the test strip CAU...

Страница 10: ...sh on the display for three seconds and then stay constant for three seconds The display will advance to the screen with the flashing blood drop icon R If the codes already match wait three seconds Th...

Страница 11: ...use only Keep your meter and lancing device clean See Caringforyour system in Section 6 NOTE If you do not have a lancing device please refer to the instructions that came with your lancing device The...

Страница 12: ...Shallower punctures work for children and most adults Deeper punctures work well for people with thick or callused skin Twist the blue or black cap until the correct setting appears NOTE A shallower...

Страница 13: ...ate an insulin reaction Choosing the right sampling site at the right time The OneTouch UltraMini Meter allows you to sample blood from your fingertip forearm or palm Forearm and palm sampling is also...

Страница 14: ...e button while continuing to apply pressure Keep holding the lancing device against your skin until a round drop of blood forms under the cap Remember Consult with your healthcare professional before...

Страница 15: ...plying a drop of blood from your forearm or palm keep your palm or forearm steady and bring the top edge of the test strip to the drop of blood with your other hand Fingertip Palm Forearm When samplin...

Страница 16: ...ot fill the confirmation window completely See Understandingerrorandothermessages in Section 7 Discard the test strip and re start the test process NOTE Do Not smear or scrape the drop of blood with t...

Страница 17: ...measure and the date and time of the test Blood glucose results are automatically stored in the meter s memory CAUTION If you test at the low end of the operating range 6 44 C and your glucose is high...

Страница 18: ...ted glucose results If you continue to get unexpected results check your system with control solution See Section 5 Control solution testing If you are experiencing symptoms that are not consistent wi...

Страница 19: ...release to turn it on After the start up test screen your most recent test result will appear on the display M also appears to indicate memory mode If you have just completed a test leave the test st...

Страница 20: ...G To avoid a possible shock Do Not insert a test strip when the meter is connected to a computer with the OneTouch Interface Cable Downloading results to a computer You can use your meter with OneTouc...

Страница 21: ...the screen with the flashing blood drop icon R If the codes already match wait three seconds The display will advance to the screen with the flashing blood drop icon R Mark the test as a control solu...

Страница 22: ...rom 5 to 1 Your result will then appear on the display along with CtL and the unit of measure Check if the result is in range Compare the result displayed on the meter to the control solution range pr...

Страница 23: ...of the meter display to indicate low battery When there is enough power for a minimum of 100 more tests the battery icon will appear After each test and when reviewing past results the battery icon w...

Страница 24: ...ctly installed with the side up If the meter still does not power on call the OneTouch Customer Care Line at 1 800 663 5521 Check the time and date After replacing the battery turn the meter on by pre...

Страница 25: ...tenance Storing your system Store your meter test strips and control solution in your carrying case after each use Store each item in a cool dry place below 30 C but Do Not refrigerate Keep all items...

Страница 26: ...cleaning solution on the meter or immerse it in any liquid Cleaning your lancing device and clear cap To clean these items wipe them with a soft cloth dampened with water and mild detergent Do Not im...

Страница 27: ...this message could be due to a test error it is safer to treat first and then do another test You may have a very high blood glucose level severe hyperglycemia over 33 3 mmol L Re check your glucose l...

Страница 28: ...he OneTouch Customer Care Line at 1 800 663 5521 Error message could be caused either by a used test strip or a problem with the meter Repeat the test with a new test strip see Section 3 Testing your...

Страница 29: ...of the system s operating temperature range 6 44 C or There may be a problem with the test strip For example it may have been damaged or moved during testing or The sample was improperly applied or Th...

Страница 30: ...st in a warmer environment with a new test strip as soon as possible For accuracy and precision data and for important information on limitations see the insert that comes with your test strips To max...

Страница 31: ...PR 11 2003 Class B Radiated Only Emissions of the energy used are low and are not likely to cause interference in nearby electronic equipment C US CAN CSA C22 2 61010 1 04 UL 61010 1 04 IEC 61010 1 an...

Отзывы: