background image

2hp 50hz Super Gorilla Owner’s Manual  © O.A.S. 2010

7

VI. Assembly Instructions

Clips - AFT051618

Motor Plate

Gasket
Material

Gasket material goes 
outside of clip holes 
on top and bottom of 
fan housing.

Gasket
Material

Collector
Barrel

Fan
Housing

Washer

Washer

Bolt

Bolt

Clip

Instructions for assembly of the Fan Blower Housing and Barrel of the Oneida Models.

1. Push clips onto inside circle on Fan Housing, making sure clip is pushed all of the way on, that the bolt 
holes are in alignment with the clip holes and that the small barrel on the clip is on the INSIDE of the Fan 
Housing as shown in diagram.

2. Stick the gasket material around the Fan Housing as shown in the diagrams, outside of the bolt circle. 
Making sure of a complete seal. Dust collection systems cannot operate effectively without being tightly 
sealed with no air leaks.

3. Put bolt through washer. then into appropriate bolt holes in Fan Housing and Barrel. Tighten bolts so 
they all are snug, then go back and fi nish tightening the bolts in a star pattern.

Proportions and sizes of parts may be

exaggerated for purposes of explanation.

It is CRITICAL that this part 

of the clip is put on the inside 

of the Fan Blower Housing as 

shown here. Otherwise you 

will not get the seal needed for 

complete dust collection!

Содержание Super Dust Gorilla

Страница 1: ...tte St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Shown with optional Stand Models may vary slightly in appearance 6_10 Super Gorilla Owner s Manual 2hp 50...

Страница 2: ...al before installing or operating system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII XVIII 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 System Start Up Informat...

Страница 3: ...ructions as well as the recommended safety practices in this manual 3 Motor is pre wired at the factory If magnetic starter trips circuit check the following 1 Dust drum securely fastened to discharge...

Страница 4: ...1 External Cartridge Filter Silencer Included with Filter Caution Cartridge Filter Media If exhaust air is vented outside you must provide make up return air Flue gases carbon monoxide can be drawn in...

Страница 5: ...4 2hp 50hz Super Gorilla Owner s Manual O A S 2010 III General Specifications Fan Performance Curves...

Страница 6: ...ing Heights w 99 cm Filter Dimensions subject to slight variation in manufacturing 2 2 5hp 92 00 6 33 cm 33 0 cm 123 cm 61 6 cm 67 5 cm Allow 2 5 5 cm from ceiling 231 1 cm 191 8 cm 168 9 cm 142 2 cm...

Страница 7: ...4 bolts 32 1 4 flat washers 32 1 4 20 Nylock nuts f9 16 Clips AFT051618 AHX000001 40 12 f10 16 Flange Bolts AFB155155 8 5 16 Clips 8 5 16 Bolts 8 5 16 Clips 8 5 16 Bolts 5i 5i Filter Plate 13 FPX01001...

Страница 8: ...the clip is on the INSIDE of the Fan Housing as shown in diagram 2 Stick the gasket material around the Fan Housing as shown in the diagrams outside of the bolt circle Making sure of a complete seal D...

Страница 9: ...ousing to Cyclone barrel Then bolt Motor and Plate to Fan Blower housing Carefully lay unit on its side and then bolt cone to barrel Lift entire unit up onto stand Unit is extremely heavy and top weig...

Страница 10: ...9 2hp 50hz Super Gorilla Owner s Manual O A S 2010...

Страница 11: ...is at the bottom 3 Attach gasket around cut out in filter plate as shown in diagram making sure there are no gaps where ends meet 4 Attach filter plate to Plenum using the 9 included elevator bolts wa...

Страница 12: ...ect cyclone and dust bin Make sure dust bin is in place and ductwork is connected to inlet before turning on the dust collector Electrical Wiring Make sure power source matches wire voltage configurat...

Страница 13: ...air nozzle at least 6 from filter Closer blasts may damage material This operation should be done with filter on the unit Dust is trapped inside filter so it will not make a mess 15 cm Filter must be...

Страница 14: ...13 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XI Wiring Diagram for Magnetic Starter 220v 1 Starter will not operate at any other voltages Starter is shown configured for 1O SFA 12 1 FLA 11 5...

Страница 15: ...k for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe...

Страница 16: ...eet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in...

Страница 17: ...inal purchaser from the date of purchase Items not manufactured by O A S are limited to their own manufacturer s warranties All electrical items such as magnetic starters remotes sensors pumps and scc...

Страница 18: ...side of Mid Gussets with 2 1 4 20 x 3 4 bolts and secure with 1 4 Flat Washer and 1 4 20 Nylock Nut Adjust the legs for the 21 or 23 cone by positioning the bolts in the appropriate position in the sl...

Страница 19: ...e BAG Gripper provides the ability to use convenient plastic bags inside your dust drum It provides a Constant negative pressure on the outside surface of the plastic bag that keeps it pulled tight ag...

Страница 20: ...19 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XVII Fan Motor Maintenance Per Baldor specifications their 2 pole motors 3600 RPM motors are to be relubricated every 5500 hours...

Страница 21: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Отзывы: