11

2hp 50hz Super Gorilla Owner’s Manual © O.A.S. 2010

IX. Filter Maintenance

External Filter Cartridge Cleaning Intervals

When unit is turned off, use compressed air to blow dust off from 

exterior of fi lter. Hold nozzle at least 6” away from fi lter pleats*. Do 

not remove bottom dust pan before or during the blow-off process! 

Let dust settle into dust pan. Unclip and dump out dust. Filter 

removal is not required.
*WARNING: A close, direct blast with the compressed air nozzle 

too close to fi lter, may damage fi lter media. Always wear safety 

glasses while blowing off fi lter.

Fan / Blower & Cyclone Outside Placement

Fan / Blower has a TEFC - Totally Enclosed Fan Cooled Motor.

Note: Use steel drum when placed outside.

Before Operation:

Mount system and connect cyclone and dust bin. Make sure dust bin is in place and ductwork is connected 

to inlet before turning on the dust collector.

Electrical Wiring:

Make sure power source matches wire voltage confi gurations on motor.

Prior to connecting to the power line, check motor plate for proper voltage. Motor is pre-wired for counter-

clockwise rotation. Fan wheel must rotate counter-clockwise if looking down on fan housing.

Use 12 gauge cord for the fan / blowers.

Lubrication:

See pg. 19 for schedule and specifi cations.

Caution: Rotating Fan Blades! Keep objects clear of outlet.

Do not operate Fan / Blower unless Cyclone and Dust Bin are in place! Motor will overheat!

Caution: Fine dust collected in fi lter is hazardous to 
your health! Do not breathe!

Shown with 

optional 

Stand.

Caution:

If exhaust air is vented outside you must provide make up / return air.

Flue gases (carbon monoxide) can be drawn into the shop from furnaces, 

water heaters or other appliances.

Содержание Super Dust Gorilla

Страница 1: ...tte St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Shown with optional Stand Models may vary slightly in appearance 6_10 Super Gorilla Owner s Manual 2hp 50...

Страница 2: ...al before installing or operating system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII XVIII 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 System Start Up Informat...

Страница 3: ...ructions as well as the recommended safety practices in this manual 3 Motor is pre wired at the factory If magnetic starter trips circuit check the following 1 Dust drum securely fastened to discharge...

Страница 4: ...1 External Cartridge Filter Silencer Included with Filter Caution Cartridge Filter Media If exhaust air is vented outside you must provide make up return air Flue gases carbon monoxide can be drawn in...

Страница 5: ...4 2hp 50hz Super Gorilla Owner s Manual O A S 2010 III General Specifications Fan Performance Curves...

Страница 6: ...ing Heights w 99 cm Filter Dimensions subject to slight variation in manufacturing 2 2 5hp 92 00 6 33 cm 33 0 cm 123 cm 61 6 cm 67 5 cm Allow 2 5 5 cm from ceiling 231 1 cm 191 8 cm 168 9 cm 142 2 cm...

Страница 7: ...4 bolts 32 1 4 flat washers 32 1 4 20 Nylock nuts f9 16 Clips AFT051618 AHX000001 40 12 f10 16 Flange Bolts AFB155155 8 5 16 Clips 8 5 16 Bolts 8 5 16 Clips 8 5 16 Bolts 5i 5i Filter Plate 13 FPX01001...

Страница 8: ...the clip is on the INSIDE of the Fan Housing as shown in diagram 2 Stick the gasket material around the Fan Housing as shown in the diagrams outside of the bolt circle Making sure of a complete seal D...

Страница 9: ...ousing to Cyclone barrel Then bolt Motor and Plate to Fan Blower housing Carefully lay unit on its side and then bolt cone to barrel Lift entire unit up onto stand Unit is extremely heavy and top weig...

Страница 10: ...9 2hp 50hz Super Gorilla Owner s Manual O A S 2010...

Страница 11: ...is at the bottom 3 Attach gasket around cut out in filter plate as shown in diagram making sure there are no gaps where ends meet 4 Attach filter plate to Plenum using the 9 included elevator bolts wa...

Страница 12: ...ect cyclone and dust bin Make sure dust bin is in place and ductwork is connected to inlet before turning on the dust collector Electrical Wiring Make sure power source matches wire voltage configurat...

Страница 13: ...air nozzle at least 6 from filter Closer blasts may damage material This operation should be done with filter on the unit Dust is trapped inside filter so it will not make a mess 15 cm Filter must be...

Страница 14: ...13 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XI Wiring Diagram for Magnetic Starter 220v 1 Starter will not operate at any other voltages Starter is shown configured for 1O SFA 12 1 FLA 11 5...

Страница 15: ...k for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe...

Страница 16: ...eet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in...

Страница 17: ...inal purchaser from the date of purchase Items not manufactured by O A S are limited to their own manufacturer s warranties All electrical items such as magnetic starters remotes sensors pumps and scc...

Страница 18: ...side of Mid Gussets with 2 1 4 20 x 3 4 bolts and secure with 1 4 Flat Washer and 1 4 20 Nylock Nut Adjust the legs for the 21 or 23 cone by positioning the bolts in the appropriate position in the sl...

Страница 19: ...e BAG Gripper provides the ability to use convenient plastic bags inside your dust drum It provides a Constant negative pressure on the outside surface of the plastic bag that keeps it pulled tight ag...

Страница 20: ...19 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XVII Fan Motor Maintenance Per Baldor specifications their 2 pole motors 3600 RPM motors are to be relubricated every 5500 hours...

Страница 21: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Отзывы: