background image

16

XIV. Terms and Conditions

  Please look over the shipped order very carefully in the presence of the delivery person for damage or 
incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping 
packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive 
concealed damage. The shipping company will not take responsibility if the damage is not noted on the 
delivery receipt. In the event of shipping damage, call O.A.S. immediately so we can expedite 
replacements. Please check in all parts within 3 days from receiving order. Notify O.A.S. immediately of any 
missing or incorrect parts. O.A.S. does not accept any claims for damage or shortage after 3 days from 
date of delivery.

Checking in Order

Limited Warranty

*Note: Motors should be protected from extreme weather to prolong motor life.
Single phase motors should only be started and stopped up to 4 - 10 times per
hour. Starting single phase motors more frequently can cause heat build up
and can cause the motor overload to trip or cause motor damage. In general,
motors should be started and stopped as little as possible for maximum
lifespan and best economy (electrical use).

  Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon 
delivery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and 
O.A.S. will make reasonable efforts to ship on or before the date states for shipment, however, O.A.S. shall 
not incur any liability for failure to ship on that date.

Delivery Risk of Loss

Returned Goods Policy

Installing a dust collection system will greatly reduce airborne dust levels in your shop. However, NIOSH recommends 

that respirators must be worn if the ambient concentration of wood dust exceeds the prescribed exposure limit. If in  

doubt wear a NIOSH mask.

Oneida Air Systems warrants products it manufactures for a period of 2 years to the original purchaser from the date of 

purchase. Items not manufactured by O.A.S. are limited to their own manufacturer’s warranties. All electrical items such as 

magnetic starters, remotes, sensors, pumps and sccessories are limited to 90 days. This warranty does not apply to defects 

directly or indirectly to misuse, negligence, accidents, abuse, repairs, or alterations or lack of maintenance. This is Oneida 

Air Systems sole written warranty and any warranties that may be implied by law, including any merchantability or fi tness, 

for any particular purpose, are hereby limited to the duration of this written warranty. O.A.S. does not warrant or represent 

that the merchandise complies with the provisions of any law or acts unless the manufacturer so warrants. In no event shall 

O.A.S.’s liability under this warranty exceed the purchase price paid for the product and any legal actions brought against 

Oneida Air Systems shall be tried in the State of New York, County of Onondaga.

Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental, contingent, special, 

or consequential damages arising from the use of our product.

Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes. This includes wood prod-

ucts that are treated, coated, or otherwise altered from their natural state.

Buyer must inform O.A.S. of any shortage or damage, by so noting in writing, on the freight delivery bill prior to signing to 

indicate receipt of shipment. All claims, including claims covered under the limited warranty, are subject to inspection and 

investigation by O.A.S. O.A.S. reserves the right to inspect, investigate all returned products before Buyer’s claim is settled. 

All products returned for a cash refund must be unused, resaleable and purchased within 30 days. There are no refunds 

on fl ex hose, custom made components or partial kit items. Kits must be returned in full (all components) for credit. There 

will be a 25% restocking fee applied to any returned items. Buyer must call and get an RMA (Return Authorization 

Number). Merchandise must be shipped to us prepaid.

2hp 50hz Super Gorilla Owner’s Manual © O.A.S. 2010

Содержание Super Dust Gorilla

Страница 1: ...tte St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Shown with optional Stand Models may vary slightly in appearance 6_10 Super Gorilla Owner s Manual 2hp 50...

Страница 2: ...al before installing or operating system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII XVIII 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 System Start Up Informat...

Страница 3: ...ructions as well as the recommended safety practices in this manual 3 Motor is pre wired at the factory If magnetic starter trips circuit check the following 1 Dust drum securely fastened to discharge...

Страница 4: ...1 External Cartridge Filter Silencer Included with Filter Caution Cartridge Filter Media If exhaust air is vented outside you must provide make up return air Flue gases carbon monoxide can be drawn in...

Страница 5: ...4 2hp 50hz Super Gorilla Owner s Manual O A S 2010 III General Specifications Fan Performance Curves...

Страница 6: ...ing Heights w 99 cm Filter Dimensions subject to slight variation in manufacturing 2 2 5hp 92 00 6 33 cm 33 0 cm 123 cm 61 6 cm 67 5 cm Allow 2 5 5 cm from ceiling 231 1 cm 191 8 cm 168 9 cm 142 2 cm...

Страница 7: ...4 bolts 32 1 4 flat washers 32 1 4 20 Nylock nuts f9 16 Clips AFT051618 AHX000001 40 12 f10 16 Flange Bolts AFB155155 8 5 16 Clips 8 5 16 Bolts 8 5 16 Clips 8 5 16 Bolts 5i 5i Filter Plate 13 FPX01001...

Страница 8: ...the clip is on the INSIDE of the Fan Housing as shown in diagram 2 Stick the gasket material around the Fan Housing as shown in the diagrams outside of the bolt circle Making sure of a complete seal D...

Страница 9: ...ousing to Cyclone barrel Then bolt Motor and Plate to Fan Blower housing Carefully lay unit on its side and then bolt cone to barrel Lift entire unit up onto stand Unit is extremely heavy and top weig...

Страница 10: ...9 2hp 50hz Super Gorilla Owner s Manual O A S 2010...

Страница 11: ...is at the bottom 3 Attach gasket around cut out in filter plate as shown in diagram making sure there are no gaps where ends meet 4 Attach filter plate to Plenum using the 9 included elevator bolts wa...

Страница 12: ...ect cyclone and dust bin Make sure dust bin is in place and ductwork is connected to inlet before turning on the dust collector Electrical Wiring Make sure power source matches wire voltage configurat...

Страница 13: ...air nozzle at least 6 from filter Closer blasts may damage material This operation should be done with filter on the unit Dust is trapped inside filter so it will not make a mess 15 cm Filter must be...

Страница 14: ...13 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XI Wiring Diagram for Magnetic Starter 220v 1 Starter will not operate at any other voltages Starter is shown configured for 1O SFA 12 1 FLA 11 5...

Страница 15: ...k for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe...

Страница 16: ...eet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in...

Страница 17: ...inal purchaser from the date of purchase Items not manufactured by O A S are limited to their own manufacturer s warranties All electrical items such as magnetic starters remotes sensors pumps and scc...

Страница 18: ...side of Mid Gussets with 2 1 4 20 x 3 4 bolts and secure with 1 4 Flat Washer and 1 4 20 Nylock Nut Adjust the legs for the 21 or 23 cone by positioning the bolts in the appropriate position in the sl...

Страница 19: ...e BAG Gripper provides the ability to use convenient plastic bags inside your dust drum It provides a Constant negative pressure on the outside surface of the plastic bag that keeps it pulled tight ag...

Страница 20: ...19 2hp 50hz Super Gorilla Owner s Manual O A S 2010 XVII Fan Motor Maintenance Per Baldor specifications their 2 pole motors 3600 RPM motors are to be relubricated every 5500 hours...

Страница 21: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Отзывы: