Mini-Gorilla Owner’s Manual     O.A.S. 2010

c

.

  Please look over the shipped order very carefully in the presence of the delivery person for damage or incom-

plete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, 

however slight, on the shipping delivery receipt. This could be an indication of extensive concealed damage. The 

shipping company will not take responsibility if the damage is not noted on the delivery receipt. In the event of 

shipping damage, call OAS Customer Service immediately at 1.800.732.4065 so we can expedite replacements. 

Please check in all parts within 3 days from receiving order. Notify OAS immediately of any missing or incorrect 

parts. OAS does not accept any claims for damage or shortage after 3 days from date of delivery.

X. Terms and Conditions

Checking in Order

  Oneida Air Systems warrants products it manufactures for a period of 1 or more years depending on the product 

to the original purchaser from the date of purchase unless otherwise specified. Items not manufactured by OAS 

are limited to their own manufacturer’s warranties. All electrical items such as magnetic starters, remotes, sensors, 

pumps, and accessories are limited to 90 days. This warranty does not apply to defects due directly or indirectly to 

misuse, negligence, accidents, abuse, repairs, alterations, improper wiring or lack of maintenance. This is Oneida 

Air Systems sole written warranty and any and all warranties that may be implied by law, including any merchant-

ability or fitness, for any particular purpose, are hereby limited to the duration of this written warranty. OAS does 

not warrant or represent that the merchandise complies with the provisions of any law or acts unless the manu-

facturer so warrants. In no event shall OAS’s liability under this warranty exceed the purchase price paid for the 

product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County 

of Onondaga.

  Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental, contin

-

gent, special, or consequential damages arising from the use of our product.

  Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes. This includes 

wood products that are treated, coated, or otherwise altered from their natural state.

Limited Warranty

*Note: Motors should be protected from extreme weather to prolong motor life. Single phase motors 

should only be started and stopped up to 4 - 10 times per hour. Starting single phase motors more fre-

quently can cause heat build up and can cause the motor overload to trip or cause motor damage. In gen-

eral, motors should be started and stopped as little as possible for maximum lifespan and best economy 

(electrical use).

Delivery Risk of Loss

  Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon deliv

-

ery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and OAS will make 

reasonable efforts to ship on or before the date states for shipment, however, OAS shall not incur any liability for 

failure to ship on that date.

Returned Goods Policy

  Buyer must inform OAS of any shortage or damage, by so noting in writing, on the freight delivery bill prior to 

signing to indicate receipt of shipment. All claims, including claims covered under the limited warranty, are subject 

to inspection and investigation by OAS. OAS reserves the right to inspect and investigate all returned products 

before Buyer’s claim is settled. All products returned for a refund must be unused and resaleable and purchased 

within the last 30 days. There are no refunds on flex hose or custom made components. There will be a 25% re

-

stocking fee applied to any returned items.

 Buyer must call and get an RMA#. (Return authorization number.) 

Merchandise must be shipped to us prepaid.
Installing a dust collection system will greatly reduce airborne dust levels in your shop. However, 

NIOSH recommends that respirators must be worn if the ambient concentration of wood dust exceeds 

the prescribed exposure limit. If in doubt, wear a NIOSH mask.

Содержание Mini GORILLA XXP010100

Страница 1: ...onal Mobile Cart and 17 Gal Drum Oneida Air Systems Inc 1001 West Fayette St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual 1 10 ZBM000024 TM U...

Страница 2: ...collection Call for ductwork design and ductwork quotes including system pricing and shipping cost Read the entire Owner s Manual before installing or operating system Proudly Made in the USA I II II...

Страница 3: ...Handling and installation should always be performed by healthy individuals Additional help may be re quired In addition to the following instructional manual care should be taken to ensure complianc...

Страница 4: ...st be taken not to damage the membrane If there is significant backside blinding compressed air may be used However forcing the dust further into the media from the backside is likely Wahing the filte...

Страница 5: ...00001 3 Thumb Nut 5 16 x 18 AFT025200 4 Nut 1 4 20 U Spring AFT155175 6 Whiz Lock Nut 5 16 AFW025000 4 Washer Flat USS 1 4 AFW180000 12 Washer Flat USS 5 16 RCP050000 1 Silicone Plug 438 x 687 x 1 RGZ...

Страница 6: ...5 Mini Gorilla Owner s Manual O A S 2010 c V Dimensions Approx 39 Approx 15 Width with Filter Approx 29 Width with Filter Mobile Cart Approx 36 Approx 62...

Страница 7: ...bracket are heavy Make sure the bracket is level when it is attached 3 The collector can only be attached to the wall bracket with the cyclone inlet in front as shown in picture Line up the holes in...

Страница 8: ...Motor and Cyclone 3 Attach the Magnetic Starter to a leg with supplied clamps with bolts if you have the mobile cart or a sturdy surface if you are wall mounting it 3 6 Attach filter to plate as shown...

Страница 9: ...en put on wheel washer through the eye bolt washer then through the tubes on the bottom of the tray as shown in diagram below then repeat on the other side 2 Before you attach the legs to the bracket...

Страница 10: ...if equipped with slot ted grease screws If motor has a purge plug remove it Motors can be re greased while stopped at less than 80 C or running Apply grease gun to fitting or grease hole Too much grea...

Страница 11: ...n Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe too small a hood port or too small a branch l...

Страница 12: ...t requires an aggregate dust collection flow rate of more than 1500 cfm cubic feet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Co...

Страница 13: ...neida Air Systems shall in no event be liable for death injuries to persons or property or for incidental contin gent special or consequential damages arising from the use of our product Oneida Air Sy...

Отзывы: