AgriShift
®
Lighting Control Unit MASTER - Model LCL-0.2
30
ANNEX C: QUICK TROUBLESHOOTING
1 - Control outputs do not seem to follow the instructions given.
a) Make sure that the control switches of the relevant outputs (located
on the front panel of the AgriShift
®
controller) are in the AUTO posi-
tion.
b) Ensure that the relevant outputs are configured in AUTO control
mode (see section 4.6 Output control).
c) If a dimmer is associated to the output, ensure that this dimmer is
fully turned to the left (AUTO position).
2 - A "Low Battery" message appears on the summary page.
a) Change the battery immediately to avoid data loss in case of power
failure (see section 2.8 Maintenance for details).
3 - Dimming outputs are erratic or jump in large steps/jump instead of
smoothly changing.
a) For three-phase installations, be sure both A and B outputs are
connected to the same phase of the main power.
4 - LED lights flicker or strobe at low dimming levels.
a) Set master to transition to off (zero power) when 5 to 10% dimming
is reached.
5 - LED lights flicker, flash, pop or behave erratically.
a) Investigate mains power for noise, voltage spikes, or distortion cau-
sed by neighboring equipment or dirty power.
b) Consider installing a power conditioner/filter.
Содержание AgriShift LCL-0.2-120V
Страница 2: ......
Страница 35: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 33 ANNEX D WIRING DIAGRAM 3 1 1...
Страница 36: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 34 NOTES...
Страница 37: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 35 NOTES...
Страница 38: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 36 NOTES...
Страница 39: ......
Страница 40: ...ONCE Inc Plymouth MN 55442 PN 30 008 00057...