background image

Installation and User Manual

AgriShift® Lighting Control Unit MASTER

 

Models LCL-0.2-120V / LCL-0.2-240V

BUILT FOR YOUR BARN

TM

Содержание AgriShift LCL-0.2-120V

Страница 1: ...Installation and User Manual AgriShift Lighting Control Unit MASTER Models LCL 0 2 120V LCL 0 2 240V BUILT FOR YOUR BARN TM...

Страница 2: ......

Страница 3: ...STALLATION COMMISSIONING AND OPERATION OPERATOR INTERFACE OPERATING PARAMETERS SYSTEM CONFIGURATION Installation and User Manual AgriShift Lighting Control Unit MASTER Models LCL 0 2 120V LCL 0 2 240V...

Страница 4: ...9 3 Operator Interface 10 3 1 Control Location and Utilization 10 3 1 1 Status Lights 10 3 1 2 Navigation Controls 11 3 1 3 Interfaces Screens 11 3 1 4 Control Switches 13 3 2 Controller Menu and Opt...

Страница 5: ...arameters 26 5 2 1 Power Expansion Master Slave Mode 26 5 2 2 Lighting Control 27 5 3 Con guration Local Settings 27 5 4 Con guration System Version 27 Annex A Speci cations LCL 0 2 120V 28 Annex B Sp...

Страница 6: ...er outputs configurable in automatic mode or in manual mode through the use of dedicated bypass switches and an in tensity knob Equipped with an intelligent processor the system offers simple and intu...

Страница 7: ...ICATION The LCL 0 2 120V and LCL 0 2 240V controllers are designed to control dimmable lighting systems used in agricultural farm buildings Any other use of these controllers can compromise the safety...

Страница 8: ...directly 5 Temperature at the installation site of the controller must lie between 0 and 40 C 32 to 104 F at all times 6 Relative humidity at the installation site of the controller must lie between...

Страница 9: ...be sealed with mastic to prevent moisture condensation inside the controller 3 Sufficient lengths of wire should be provided to allow the removal of all equipment during service operations 4 Power ca...

Страница 10: ...menu section 5 1 3 For safety reasons all newly configured outputs are automatically set to MANUAL mode Switch all outputs from MANUAL to AUTO MATIC mode See section 4 6 Output Control 4 Place the fr...

Страница 11: ...too low Please proceed to its immediate re placement to avoid data loss in case of power failure Follow these steps to replace the battery 1 Open the case and locate the position of the battery locat...

Страница 12: ...of communication is detected or if the communication bus is inactive Warning Alarm Lights up in the following cases Blinking if either the manual control or simulation option is activated The manual...

Страница 13: ...formation on the screens of the AgriShift system Menu Menu pages present and provide access to a list of submenus The left arrow indicates the selected item Use the keys and to select the des ired sub...

Страница 14: ...e or press to cancel Output A Enable Dimmer Dimmer 1 Calibration Edit Field selected Dimmer 1 Output A Field selected in editing mode Editing ON OFF variables To edit an ON OFF checkbox parameter in t...

Страница 15: ...eously if both are set on manual mode Control Switches in the ON position Manual Intensity Adjustment Knob 3 2 CONTROLLER MENU AND OPTIONS 3 2 1 General Lighting outputs state Master controller LCL 0...

Страница 16: ...1 SUMMARY The summary page shows the following information Current lighting intensity Production day whether the controller is in Non Production mode Controller time and date If the system is in manu...

Страница 17: ...MASTER Model LCL 0 2 15 SECTION 4 4 3 NAVIGATION DIAGRAM MAIN MENU HOME Return to main menu LIGHTING PRODUCTION Summary Curve Temporary Override OUTPUT CONTROL CONFIGURATION Outputs Advanced settings...

Страница 18: ...on manual operating mode The intensity is set by the Manual Intensity Adjustment Knob h Dim for variable output only the lighting output takes the setpoint of its external dimmer currently set to man...

Страница 19: ...h The following page presents a lighting curve programming summary To edit or view details select a period and press or select to create a new period then press Period Curve Daylight 95 60 0 4 60 5 20...

Страница 20: ...cle simulate the natural sunrise and sunset to reduce animal stress Growth and weight gain are enhanced by the introduction of momentary light stimuli during a light cycle Period start 0 to 500 days D...

Страница 21: ...next period For the last period defined the Day light Intensity remains steady throughout the period even if the gradual mode is selected Daylight Intensity Day Daylight Start Period 2 Daylight Start...

Страница 22: ...00 00 00 00 b 12 1 2 Select the option Stimuli Edit to bring up the following page For each stimulus set the following para meters Enable Select this option to enable the sti mulus Start Starting tim...

Страница 23: ...tically deactivated Temporary Override 55 Current Intensity Manual Control 30 min Activation Duration 0 Manual Intensity The temporary manual override mode can be ac tivated deactivated in any program...

Страница 24: ...when starting a new production Modify the day only Allow to change the production day without deleting the water consumption history Delete all history Modify the day only Cancel Changing production...

Страница 25: ...rol page To change the control mode of an output select the desired output and press The following page will appear AUTO control Control Output A Mode AUTO MANUAL control Control Output A Mode Manual...

Страница 26: ...desired submenu among the following and press Configuration Outputs Advanced Parameters Local Settings System Version EXTERNAL DIMMER FUNCTIONING If the dimmer is fully turned to the left AUTO the li...

Страница 27: ...levels 3 2 Adjust the Minimum Intensity Since the main supply voltage may somewhat vary from one location to another it is required to adjust the minimum lighting intensity This feature is provided t...

Страница 28: ...Intensity 75 and Intensity 100 At any time the output can be disabled by selecting Stop MASTER mode SLAVE mode Advanced Parameters Power Expansion Master Mode Output A Master Output Lighting Control I...

Страница 29: ...ocal settings Language Time Date English 2012 02 15 10 03 00 Format Date AAAA MM JJ Format Time 24 h Master output in master mode only Determines the output A or B whose value will be followed by the...

Страница 30: ...pported must be respected Refer to the nameplate on the controller Case Dimensions 8 7 X 10 6 X 5 5 Temperature 0 to 40 C 32 to 104 F Storage 15 to 50 C 5 to 122 F Relative humidity 5 to 90 without co...

Страница 31: ...pported must be respected Refer to the nameplate on the controller Case Dimensions 8 7 X 10 6 X 5 5 Temperature 0 to 40 C 32 to 104 F Storage 15 to 50 C 5 to 122 F Relative humidity 5 to 90 without co...

Страница 32: ...ow Battery message appears on the summary page a Change the battery immediately to avoid data loss in case of power failure see section 2 8 Maintenance for details 3 Dimming outputs are erratic or jum...

Страница 33: ...DIAGRAM 2 FOR DETAILS SEE DIAGRAM 2 FOR DETAILS FOR THREE PHASE INSTALLATIONS LINE IN 1 FOR BOTH A AND B OUTPUTS SHOULD BE OF THE SAME PHASE AS L1 AGRISHIFT LCL 0 2 MAIN BOARD The electrical loads dis...

Страница 34: ...3 FOR POWER EXTENSION CONNECTION DETAILS 2 LINE IN 1 FOR BOTH A AND B OUTPUTS SHOULD BE OF THE SAME PHASE AS L1 FOR THREE PHASE 1 RESISTIVE INPUT TRIAC VARIABLE OUTPUTS The electrical loads distributi...

Страница 35: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 33 ANNEX D WIRING DIAGRAM 3 1 1...

Страница 36: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 34 NOTES...

Страница 37: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 35 NOTES...

Страница 38: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 36 NOTES...

Страница 39: ......

Страница 40: ...ONCE Inc Plymouth MN 55442 PN 30 008 00057...

Отзывы: