background image

Harmony

TM

 Low Bed 

19

7.5 

integrated pump Holder

The footboard of the Harmony Low Bed features an integrated pump holder designed to easily attach 
most air mattress pumps, sequential compression devices (SCDs), and other equipment designed to be 
hung on a bed frame. If a specific pump does not securely attach to the integrated pump holder, an 
optional attachment is also available. 

7.6 

auxiliary power Outlet

The Harmony Low Bed is equipped with a 110v auxiliary power outlet. The outlet receives power through 
a dedicated black power cord. If the auxiliary power outlet is not powering a device, check that the 
black power cord is plugged into a power supply and that the circuit breaker (located next to the 
power outlet) does not need to be reset. 

7.7 

Optional Trapeze/patient Helper

The optional trapeze/patient helper has a limited safe working load. Refer to trapeze label for specific 
weight capacity. The trapeze handle height can be adjusted by shortening the chain length. To shorten 
the chain length, grasp the handle and position at the desired height, then hang the appropriate chain 
link on the hook located on the patient helper bar.  

The trapeze has three positions:

 

a)   Centered 

Positions the trapeze above 
the patient’s upper torso to 
provide assistance during 
positioning. 

 

b)   Off set 

Positions the trapeze and 
patient helper bar to the 
side of the bed for assistance 
during egress. 

 

c)   Storage 

Positions the patient helper 
behind the head board, 
allowing clear patient access 
to caregivers.

B

細部放大圖 B 

比例 1 : 8

B

細部放大圖 B 

比例 1 : 8

B

細部放大圖 B 

比例 1 : 8

Содержание Harmony Low Bed

Страница 1: ...Smarter Products Better Performance Harmony Low Bed User Manual ...

Страница 2: ...CareTM HarmonyTM is a trademark of UHS The contents of this user manual may be subject to change without prior notice For copies of the most up to date user manual or more information please visit our web site www oncaremedical com For questions please submit at www oncaremedical com or contact UHS at 800 847 7368 or www uhs com HARMONYMANUAL0412 ...

Страница 3: ...nction and Settings 13 4 0 Battery Backup System 13 5 0 MANUAL Bed CONTROLS 14 5 1 Side Rails 14 5 2 Manual Cardiopulmonary Resuscitation CPR Function 15 5 3 Foot Extension Bed Deck 15 5 3 1 To Extend 15 5 3 2 To Retract 15 5 4 Foot Section Height Adjustment 16 5 4 1 To Elevate Floor Section Horizontally 16 5 4 2 To Lower Floor Section 16 5 5 Manual Brake Release 17 6 0 HANDSET OPERATION 17 7 0 AD...

Страница 4: ...atient safety A minimum deck height below 10 bed exit alarm and triple guard anti entrapment system help minimize patient injuries In addition easy to use controls such as the one touch electronic central brake and steer let caregivers focus on patient care These features give you a smarter better performing option for acute care the Harmony Low Bed 4 Harmony Low Bed ...

Страница 5: ...egrated pump holder Bed length extension Auto contour Auxiliary power outlet Patient control hand pendant Optional Trapeze Patient helper Specifications Deck Height Low High Overall Length Overall Width Sleep Deck Weight Capacity Head Section Adjustment Knee Gatch Adjustment Trendelenburg and Reverse Trendelenburg Caster Diameter Electronics Volts Ampere Rating Patient Touch Current Leakage 9 875 ...

Страница 6: ...l UHS office or call 1 800 847 7368 OnCArE HArmOnyLOWBED 1211 2011 Universal Hospital services Inc All rights reserved HArmOny Harmony Low Bed Quick reference Guide LIGHT Press and release to switch under bed light on off BRAKE Press and release to set brake on off When off white back light will flash STEER Press and release to set one foot end caster to a rotational lock position CPR Press and ho...

Страница 7: ... Head End Foot Board Control Panel 2 0 QUICK START SET UP 1 Plug bed into wall electrical outlet 2 Place all linens and accessories on bed 3 Zero the bed scale See 3 15 4 Lower bed to appropriate transfer height 5 Lock casters by pushing Brake button 6 Bed is now ready for patient use 3 0 HARMONY LOW BED CONTROLS ...

Страница 8: ...ction The knee gatch adjustment buttons allow the thigh section to be adjusted between 0 to 35 Operation To move the knee gatch section up or down press and hold the appropriate button with the symbol as depicted 3 4 Chair Function Chair positioning provides synchronized movement of the head section knee gatch and Reverse Trendelenburg in one operation Operation Press and hold to move the bed into...

Страница 9: ...priate position CAUTION The Trendelenburg positions should only be set under clinical advisement 3 8 Reverse Trendelenburg Function The Reverse Trendelenburg button allows the bed to be positioned in a foot down head up position Reverse Trendelenburg position is achievable between 0 and 14 Operation Press and hold to move the bed deck to the desired angle digitally displayed briefly in the control...

Страница 10: ...e button until the desired position is reached 3 13 Nurse Call Button Function The nurse call button sends a signal to the nurse call system when pressed Please note this feature will only communicate when properly connected to a nurse call system See 7 1 Operation Press and release to send a signal to the nurse call system 3 14 Function Lockout Function The function lockout button disables operat...

Страница 11: ...WT CHANGE ZERO ZERO KEY UNLOCK ZERO KEY LOCK CHANGE LBS KGS KGS LBS PREVIOUS WEIGHT 099 9 KGS 220 2 LBS CHANGE WEIGHT 10 LBS LOCK LBS KGS ANGLE ZERO WT HOLD RANGE LOCK ANGLE ZERO SERVICE MENU ADJUST WEIGHT EXIT MENU A D TEST MODE EXIT MENU RESET ALL WARNING WEIGHT 0 1 2 3 4 5 6 0 1 0 1 0 1 2 3 4 5 6 7 ...

Страница 12: ... the displayed weight of the new patient will appear indicating a stabilized value has been recorded at this moment the value will be saved and locked into the scale memory automatically The bed exit alarm can now be set 3 Check patient s data a Patient s Weight Press and release button to display patient weight b Patient s Weight Change Press and release button twice to display options Press and ...

Страница 13: ...ustments will be slower when the power cord is unplugged and the bed is powered from its battery backup system 3 17 Bed Exit Alarm System 3 17 1 Bed Exit Alarm Function and Settings a With patient in bed press and release the button and scroll through the zones to select the appropriate sensitivity zone 1 2 or 3 An indicator light will illuminate next to the selected zone b Select the appropriate ...

Страница 14: ...on There is no lock in this position From down position up to mid level position While holding the upper hand hold of the side rail lift the side rail to the mid level position the PUSH lever will automatically click into its locked position From mid level position to up position While holding the upper hand hold of the side rail push the green PUSH lever with either the hand or thigh to release l...

Страница 15: ...dles are positioned in the pelvic area on both sides of the bed The manual release function returns the bed s head section to a fully down position in the event of an emergency resuscitation To manually lower the head section in an emergency pull out one of the red release handles marked CPR NOTE If manual CPR is utilized the side rail will display the last head of bed angle position To reset the ...

Страница 16: ...ratchet struts that will produce a clicking sound as the spring loaded locking mechanisms travel past the range of available locking positions Once the desired position has been reached gently allow the foot panel to lower The locking mechanism will automatically find the first available ratchet position 5 4 2 To Lower Floor Section While grasping the outer edges of the foot section panel close to...

Страница 17: ...bel reading MECHANICAL BRAKE OVERRIDE SOCKET Slide the 11 mm socket wrench from the storage bracket located behind the head foot wheel assembly Use the wrench to turn the override socket clockwise 1 4 turn Repeat at the other end of the bed and the brake will be released To re engage the electronic braking system return the manual release to its original position by turning it counter clockwise 1 ...

Страница 18: ...contact with a pressure plate the bed will not lower If the bed is in the process of lowering and has traveled at least 4 inches below the highest bed height setting the bed will stop and raise approximately 1 5 inches to free any potential obstruction c Weight Scale System The weight scale system is designed to detect when the bed frame comes into contact with an object while lowering If that occ...

Страница 19: ...ircuit breaker located next to the power outlet does not need to be reset 7 7 Optional Trapeze Patient Helper The optional trapeze patient helper has a limited safe working load Refer to trapeze label for specific weight capacity The trapeze handle height can be adjusted by shortening the chain length To shorten the chain length grasp the handle and position at the desired height then hang the app...

Страница 20: ...cleaning disinfecting products for optimal results CAUTION Prior to the commencement of any disinfection process make sure the power cord is disconnected CAUTION Wear appropriate protective gloves safety glasses and other personal protective equipment at all times during the cleaning disinfection process 8 2 Disinfecting Use of a microfiber washcloth is recommended during the cleaning and disinfec...

Страница 21: ...tal Services Inc UHS 6625 West 78th Street Suite 300 Minneapolis Minnesota 55439 Phone 952 893 3200 800 847 7368 Fax 952 893 0704 For complaints or reportable events please contact Prius Healthcare USA 580 Corporate Center 4025 Tampa Road Suite 1117 Oldsmar FL 34677 Phone 813 854 5464 Fax 813 854 5442 9 0 WARRANTY AND SERVICE ...

Страница 22: ...Smarter Products Better Performance ...

Отзывы: