NBSG16BAEVB, NBSG16VSBAEVB
http://onsemi.com
7
Setup Test Configurations For Single-Ended Operation
Single-Ended Mode – Small Signal
Step 2:
Input Setup
2a: Calibrate VNA from 1.0 GHz to 12 GHz.
2b: Set input level to –35 dBm at the input of DUT.
Step 3:
Output Setup
3a: Set display to measure S21 and record data.
Single-Ended Mode – Large Signal
Step 2:
Input Setup
2a: Calibrate VNA from 1.0 GHz to 12 GHz.
2b: Set input levels to +2 dBm (500 mV) at the input of DUT.
Step 3:
Output Setup
3a: Set display to measure S21 and record data.
Figure 5. NBSG16/16VS Board Setup – Frequency Domain (Single-Ended Mode)
50
GND
D
D
V
BB
Q
Q
V
EE
= -1.3 V (3.3 V op)
GND
V
TT
= 0 V
V
EE
V
BB
Rohde & Schwartz
Vector Network Analyzer
Bias T
50
GND
PORT 2
PORT 1
GND
50
C1
C1
V
CC
= 2.0 V
V
CC
V
TT
= 0 V
GND
V
CTRL
NBSG16VS
ONLY
C2