NBSG16BAEVB, NBSG16VSBAEVB
http://onsemi.com
3
OUT
OUT
TRIGGER
Channel 1 (80E01)
TRIGGER
Amplitude = 500 mV
Offset = 660 mV
Advantest D3186
Signal Generator
(12 GHz)
D
D
V
CC
= 2.0 V
V
CC
V
BB
Q
Q
Tektronix TDS8000
Digital Oscilloscope
V
EE
= -1.3 V (3.3 V op)
V
EE
= -0.5 V (2.5 V op)
V
TT
= 0 V
GND
V
TT
= 0 V
GND
Figure 2. NBSG16/16VS Board Setup - Time Domain (Differential Mode)
NOTE:
All differential cable pairs
must be matched.
WARNING: V
CTRL
must not be connected for NBSG16 evaluation board connection or damage may result
Channel 2 (80E01)
V
EE
V
BB
C1
C1
V
CTRL
NBSG16VS
ONLY
C2
Setup (continued)
Setup Input Signals
Step 3:
3a: Set the signal generator amplitude to 500 mV.
NOTE:
The signal generator amplitude can vary from 75 mV to 900 mV to produce a 400 mV DUT
output.
3b: Set the signal generator offset to 660 mV (the center of a nominal RSECL output).
NOTE:
The V
IHCMR
(Input High Voltage Common Mode Range) allows the signal generator offset to
vary as long as V
IH
is within the V
IHCMR
range. Refer to the device data sheet for further
information.
3c: Set the generator output for a PRBS data signal, or for a square wave clock signal with
a 50% duty cycle.
Connect Output Signals
Step 4:
4a: Connect the outputs of the device (Q, Q) to the oscilloscope. The oscilloscope
sampling head must have internal 50
termination to ground.
NOTE:
Where a single output is being used, the unconnected output for the pair
must be terminated to
V
TT
through a 50
resistor for best operation. Unused pairs may be left unconnected. Since
V
TT
= 0 V, a standard
50
SMA termination is recommended.