9051_Bedienungsanleitung_C1_Rev2_EN_UK – Stand 08.08.2018 TS / MB
16
5.3 Initialisation / Reset
After the installation, or if there is a fault at the table, or after disconnecting the connection between the drives
and the controller, the controller of the table has to be initialised.
If the controller expects a fresh initialisation, the table can be moved only down, with a reduced speed. For hand
switch versions with a display,
is displayed during the initialisation movement.
For initialising, move the table into the lowermost position. To that end, press the down key on the hand switch
till all the drives have reached the lowermost position. Now, when you release the key, the table moves into the
minimal position.
Releasing the button too early can result in a malfunction at the table. If that should happen, you must repeat
the procedure.
Attention:
The top limit stop of the controller is preset. For this reason, use only controllers that
were supplied as suitable for the respective desk base.
Danger:
The optionally available corrosion protection is
not activated
during any reset process.
During this process, always watch out for the possible danger of being crushed.
6
Control
6.1 Normal operation (with all hand-switch variants)
Use the "up" and "down" buttons to move the desk up or down in the direction of the arrow. The desk stops
when it reaches the limit positions. Keep the button pressed until the desired position has been reached.
6.2 Operation with STAND.MOVE M1.0 and M3.0
Hand switch Easy - M1.0
Hand switch Easy - M3.0
“Up”
“down”
“Up”
“Down”