Error Messages
111
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
Error Messages
This section outlines the error messages displayed on the Amplifier Unit and the
countermeasures for those messages.
Display
Error
Countermeasure
Error-bright
Saturated light amount intensity,
measurement error.
• Install so that the distance between the
Sensor Head and the workpiece is
within the measuring range.
Error-channel
• There is only one Amplifier
Unit even though mutual
interference prevention is set
to ON.
• There is only one Amplifier
Unit even though two-Sensor
operation is set to ON.
• If two or more Amplifier Units have
been installed, turn OFF the power
supply and check that the Amplifier
Units and Calculating Units are
connected correctly.
• If only one Amplifier Unit is being used,
connect another Amplifier Unit
temporarily and turn OFF mutual
interference prevention and two-
Sensor operation, or initialize the
setting data.
Error-channel
Two Amplifier Unit
communications error.
Error-dark
Insufficient received light
intensity, measurement error.
• Install so that the distance between the
Sensor Head and the workpiece is
within the measuring range.
Error-head
The Sensor Head is
disconnected. Or, a sensor
communications error has
occurred.
• Turn OFF the power supply, check the
Sensor Head connection, and then
turn ON the power supply again.
• If the above countermeasure does not
solve the problem, the Sensor Head is
malfunctioning. Replace the Sensor
Head.
Error-head
Error-head
Error-head
Sensor Head laser error.
Error-head
The Sensor Head internal
memory is in error.
Error-head
Содержание ZX2 Series
Страница 33: ...2 FLOW OF OPERATION FLOW OF OPERATION FLOW OF OPERATION 34 ...
Страница 37: ...3 BASIC SETUP BASIC SETUP BASIC SETUP 38 ...
Страница 109: ...6 TROUBLESHOOTING TROUBLESHOOTING Troubleshooting 110 Error Messages 111 ...
Страница 113: ...7 SPECIFICATIONS SPECIFICATIONS Specifications and Dimensions 114 Timing Charts 119 Engineering Data Typical 122 ...