Section 5
Selecting Banks
Selecting Banks
Up to four setting patterns can be stored in the ZJ-SD, and a set of these patterns is called a
"bank."
• Four banks can be selected.
• Banks are switched by external input leads or the amplifier (bank switching in the FUN mode
[BANK]).
• Switching by external input leads is possible only in the RUN mode.
• Measurement stops during bank switching. Measurement is resumed after the setting data in the
banks is loaded to RAM and setting processing ends.
■
Procedure for switching banks from an external input lead
The following describes the procedure for switching banks using external input leads (8), (9), (10) and (11) in
the RUN mode.
Switching how input leads are to be used
1.
Turn the pink (8) Bank shift input ON.
The functions of input leads (9), (10) and (11) change as follows:
Orange (9) Zero reset input
→
Execution of bank switching
Purple (10) Timing input
→
Bank selection 1
Red (11) Reset input
→
Bank selection 2
Turn pink (8) Bank shift input OFF when not switching banks.
Switching
Bank is switched by [External input lead] or in FUN mode [BANK].
BANK 0
Setting data
Switching
Switching
BANK 1
Setting data
Switching
BANK 2
Setting data
BANK 3
Setting data
Brown
Blue
White
Green
Gray
Black
Pink
Orange
Purple
Red
Shield
(1) 24 VDC power
(2) GND
(3) OPE1 judgment output
(4) OPE2 judgment output
(5) OPE3 judgment output
(6) Linear output
(7) Linear GND
(8) Bank shift input
(9) Zero reset input
(10) Timing input
(11) Reset input
operation2.book Page 88 Wednesday, November 29, 2006 2:56 PM