![background image](http://html1.mh-extra.com/html/omron/zfv-series/zfv-series_user-manual_744103077.webp)
74
Section 3
SETUP
ZFV
User’s Manual
Section 3
Customizing Measurement conditions
●
Specifying edge detection conditions
Set this when [EDGE] is selected to [MODE].
Set the direction in which edges are searched and the change in density.
• Selecting the color of edges
Select the direction of density change for the edge to be detected.
MENU Mode-[CUSTM]-[MODE DTL]-[COLOR]
• Selecting the edge detection direction
Select the direction in which edges are searched.
MENU Mode-[CUSTM]-[MODE DTL]-[DIRECTION]
Setting
Description
WHITE
A change from dark to light is judged as an edge.
BLACK (default value)
A change from light to dark is judged as an edge.
Setting
Description
(default value)
Searches from bottom to top.
Searches from top to bottom.
Searches from left to right.
Searches from right to left.
COLOR : BLACK
EDGE:
Example)
To correction position by this edge